Electrical Schematic
Unfold/Down and Up/Fold Microswitches:
The
Series
03
CL917IB features a new Unfold/Down
and Up/Fold microswitch assembly. The
microswitch assembly is located in the pump
side tower (shown below).
When adjusting microswitches, stop block
positioning and bridge plate positioning must be
viewed. A combination of adjustments may be
required to achieve a proper balance. In the
event that one of these microswitches requires
adjustment, refer to pages 38 and 39 of this
manual for Floor Level Guideline Adjustments.
Adjust microswitches as outlined below.
Adjustment:
Adjustment procedures remain the
same (adjustment Allen screws in place of hex
bolts). Use a 3/16" Allen wrench to turn the two
stainless steel Allen adjustment screws to
reposition the limit switches. Adjust these
microswitches as outlined below and on
Microswitch Adjustment Instructions decal 24490
(posted on tower).
Turn adjustment
bolt clockwise to
stop platform
unfold function
sooner.
Turn adjustment
bolt counter-
clockwise to
allow platform to
unfold further.
Unfold/Down
Microswitch:
Turn adjustment
bolt counter-
clockwise to stop
platform raise
function sooner.
Turn adjustment
bolt clockwise to
allow platform to
raise further.
Up/Fold
Microswitch:
Improper microswitch
adjustment may
result in serious
bodily injury and/or
property damage.
WARNING
F
Series
03
CL917IB
Unfold/Down and Up/Fold
Microswitch Assembly 975-3121A
Series
03
CL917IB
Floor Level Guideline Adjustments
The Electrical Schematic appearing in Supple-
ment 30067 is applicable for Series
03
CL917IB
lift models. Please refer to Supplement 30067.
Microswitch
Adjustment Instructions
Decal 24490
Aluminum Extrusion
UHMW Sliding
Microswitch Mounts (2)
Stainless Steel
Adjustment Screws (2)
Microswitches