Operating instructions 

 

Salt/ Mineral Requirements: 

All combination units require 3500-4500ppm salt/mineral levels 

Using only refined swimming pool salt or minerals, add the desired quality to the swimming 
pool water. To assist in the rapid dissolving and mixing, sweep or brush the solids until they 
are fully dissolved.  

Note:

 

Undissolved salt may result in staining of your pool’s interior walls.

 

Achieving the correct salt/mineral levels: 

For best results, the salt concentration in the pool water is required to be within an average 
range of approximately 3,500 to 4,500 parts per million (ppm). These figures are 
temperature dependant. In summer time as temperature rise salt levels may require slight 
reduction while in winter time the reverse may be true to allow optimum performance of 
the unit. 

New Pools 

 

Ensure the Salt/mineral cell is switched off until the salt/minerals have been 
completely dissolved in the pool 

 

To achieve the correct salt/mineral levels in new pools you need to know the pool 
capacity, you can then work out the amount of salt/minerals required in kilograms (2 
x 20kg bags per 10,000L),  
For example: pool size   60,000L = 240KG of salt/minerals 

Existing Pools 

To establish the salt level in an existing pool, take a water sample to your local pool shop for 
testing, they will tell you the current salt/mineral levels and advise the correct course of 
action required 

 
Master Switch 

Off:

 The system will not operate  

Auto

: The time clock will automatically switch your pool equipment on or off at your 

designated times.  

Manual

: The timer is by-passed, the system will operate all functions permanently  

 

Set the sanitation switch to the “on” position

 

 

Set the master switch to “manual” position to turn the unit on

 

 

Once the salt/minerals have been added and dissolved turn the cell production dial 
to the required position based on the season and the size of the pool (set to max 
output to start with and adjust down as required) 

Summary of Contents for Ozone Swim 1000

Page 1: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 1 15 User Manual Ozone Swim 1000 2000 and 3000 Series...

Page 2: ...t proper flow or water circulation as this may cause damage to the unit CAUTION This unit is not intended for use with temporary or fold able storable pools All pipe work associated with this system i...

Page 3: ...17 ENG rev 2 0 P a g e 3 15 Contents Control Unit Features 4 Installation Guide 5 Important Notes 6 Installation Layout Drawings 7 Operating instructions 11 Maintenance 12 Water Chemistry balancing In...

Page 4: ...e run indicator 7 Pump Outlet Socket 2 Chlorine Cell output display 8 Air Filter 3 Fuse 9 Ozone Output 4 Sanitation Switch 10 Positive Cell Lead red 5 Master Switch 11 Negative Cell Lead black 6 Chlor...

Page 5: ...umb chlorine cell onto return pipe after filter ensuring there is a gas trap see images below Step 3 Plumb Ozone injector manifold after chlorine cell on the return line of the pool ensuring direction...

Page 6: ...sion values In situations where a heater is incorporated the Ozone Swim cell housing must be installed after the heater Should a solar heating system be installed the housing must be plumbed after the...

Page 7: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 7 15 Ozone Swim 1000 2000 3000 Installation Layout Drawings Standard Non Flooded install...

Page 8: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 8 15 Flooded Installation For installations where control box is below water level...

Page 9: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 9 15 Installation with De Gas Chamber...

Page 10: ...neral cell is switched off until the salt minerals have been completely dissolved in the pool To achieve the correct salt mineral levels in new pools you need to know the pool capacity you can then wo...

Page 11: ...ff peak tariff we recommend the use of an appropriate battery backup time clock for that purpose Checking Chlorination output The chlorine cell output controller regulates the amount of chlorine produ...

Page 12: ...f 1 15 25 or 28 indicates the Amperage current being applied to the cell OF Cell output control knob is turned off the Ozone Swim s chlorination has been manually switched off dg Automatic cleaning cy...

Page 13: ...ur pool s application and location Water Chemistry balancing Information Regular water testing must be performed to ensure the water Is within the recommended ranges see below Chlorine 1 3 ppm Hardnes...

Page 14: ...d remove and replace water as required No display No mains power Ozone Swim plug removed from power point Ozone Swim fuse blown Unit is turned off Ensure there is mains power available Ensure Ozone Sw...

Page 15: ...ducts are designed and tested to conform to AS NZS 3136 AS NZS 3100 To comply with this standard the chlorinator must not be installed in the pool zone Trademarks Throughout this document trademark na...

Reviews: