Ozone Swim 1000, 2000 and 3000 series User Manual
–
JULY 2017 ENG rev 2.0
P a g e
12 | 15
•
Check that there is suction at the air filter on the bottom of the power pack
•
Check there is bubbles at the return jets when the system is running
Cell output display definitions
Your Ozone Swim is fitted with digital display. During operation of your Ozone Swim the
display will illuminate relevant to the degree at which the chlorine output control has been
adjusted. Y
ou can increase or decrease chlorine output to suite your pool’s requirements. As
you increase the output (by turning the control knob clockwise), the display will indicate the
Amps reading to the cell, you have full control of chlorine production merely by adjusting
the chlorine controller and illuminating the number of lights to satisfy your chlorine
demand.
The Ozone Swim also has on board diagnostics to indicate any issues with the system (see
table below for definitions)
1-xx
A value in the range of 1-15, 25 or 28
indicates the Amperage current being
applied to the cell
OF
Cell output control knob is turned off, the
Ozone Swim’s chlorination has been
manually switched off
dg
Automatic cleaning cycle beginning, the
self-cleaning function is beginning, this is
only displayed for a short period
Pb
(flashing)
there is insufficient water flow
through the cell to produce, if this persist
please refer to troubleshooting
OL
(flashing) Overload condition (see
troubleshooting)
Maintenance
Replace the check valve in the ozone output line:
Every 12 months or as required, the
Teflon check valve prevents water from returning to the system, flooded systems (below
water level) require a water trap (drain valve) to protect the system in the event that the
check valve fails, to replace the check valve simply pull the delivery line off the check valve
at both ends and replace with new check valve
Ozone Filter replacement:
Regularly (every 3-6 months) replace the Ozone air filter located
under the control unit, to remove the filter turn it anticlockwise, remove the old cotton
wool and replace with half a standard cotton wool ball, only hand tighten the filter when
refitting.