Troubleshooting 

Fault  

Potential Causes 

Action required 

Cell output display 

flashing “Pb” 

continuously (no 
water flow) 

•Pump turned off or disconnected                               
•valves closed                                                                       

gas sense wire at cell disconnected 

•Ensure pump is on                                                     

                                           

•Ensure correct valves are 

open,                                 

•reconnect sense wire at cell

 

Low salt indicator 
flashing  

•Salt level in pool has dropped too low                                                 

     

•Pool water temperature is low                                                   
•Cell has calcified Cell has failed

 

•Take sample of water to pool shop and 

check salt level 

 add salt as 

recommended                                                                              

• Add salt and turn chlorinator output 

down until the water is warmer                                                             

• Ensure cell is clean

 

High Salt indicator 
flashing 

•Too much salt has been added to the pool

 

•take 

a sample to your local pool shop to 

confirm salt levels and remove and 
replace water as required 

No display 

•No mains power                                                                          
•Ozone Swim plug removed from power point                 

                                                                            

•Ozone Swim fuse blown                                                            
•Unit is turned off

 

•Ensure there is mains power available                                        

                

•Ensure Ozone Swim is plugged into 

power point and its turned on                                                                        

•Check fuse condition and call technician 

if blown                                                                                                     

•Ensure manual mode and sanitation are 

switched on  

Low/No Chlorine 

•Insufficient run times                                                                          
•Incorrect cell production setting        

                                                                           

•Low/high Salt levels

 

•Loose connections at the cell (red & black)

 

• Adjust run times to allow more 

production                                                                                  

•increase cell production                                                                            
•Check/adjust salt levels to be within 

required range 

Disconnect leads, then 

reconnect leads 

firmly 

No Ozone light 

• LED failed               

                                                                    

• Ozone Module Failed

 

•Call Ozone Swim technician

 

Cell output flashing 

“OL” 

 

• Possible short circuit in cell (debris).                                                                    

   

•Extremely high salt levels

 

•Remove cell and check for any debris 

and clean                                                                       

•Check and adjust salt levels  

 

Water dripping out of 
drain valve (Flooded 
systems) 

• Teflon Check valve 

has failed 

•Replace Teflon Check valve 

 

 

 

 

 

 

Summary of Contents for Ozone Swim 1000

Page 1: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 1 15 User Manual Ozone Swim 1000 2000 and 3000 Series...

Page 2: ...t proper flow or water circulation as this may cause damage to the unit CAUTION This unit is not intended for use with temporary or fold able storable pools All pipe work associated with this system i...

Page 3: ...17 ENG rev 2 0 P a g e 3 15 Contents Control Unit Features 4 Installation Guide 5 Important Notes 6 Installation Layout Drawings 7 Operating instructions 11 Maintenance 12 Water Chemistry balancing In...

Page 4: ...e run indicator 7 Pump Outlet Socket 2 Chlorine Cell output display 8 Air Filter 3 Fuse 9 Ozone Output 4 Sanitation Switch 10 Positive Cell Lead red 5 Master Switch 11 Negative Cell Lead black 6 Chlor...

Page 5: ...umb chlorine cell onto return pipe after filter ensuring there is a gas trap see images below Step 3 Plumb Ozone injector manifold after chlorine cell on the return line of the pool ensuring direction...

Page 6: ...sion values In situations where a heater is incorporated the Ozone Swim cell housing must be installed after the heater Should a solar heating system be installed the housing must be plumbed after the...

Page 7: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 7 15 Ozone Swim 1000 2000 3000 Installation Layout Drawings Standard Non Flooded install...

Page 8: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 8 15 Flooded Installation For installations where control box is below water level...

Page 9: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 9 15 Installation with De Gas Chamber...

Page 10: ...neral cell is switched off until the salt minerals have been completely dissolved in the pool To achieve the correct salt mineral levels in new pools you need to know the pool capacity you can then wo...

Page 11: ...ff peak tariff we recommend the use of an appropriate battery backup time clock for that purpose Checking Chlorination output The chlorine cell output controller regulates the amount of chlorine produ...

Page 12: ...f 1 15 25 or 28 indicates the Amperage current being applied to the cell OF Cell output control knob is turned off the Ozone Swim s chlorination has been manually switched off dg Automatic cleaning cy...

Page 13: ...ur pool s application and location Water Chemistry balancing Information Regular water testing must be performed to ensure the water Is within the recommended ranges see below Chlorine 1 3 ppm Hardnes...

Page 14: ...d remove and replace water as required No display No mains power Ozone Swim plug removed from power point Ozone Swim fuse blown Unit is turned off Ensure there is mains power available Ensure Ozone Sw...

Page 15: ...ducts are designed and tested to conform to AS NZS 3136 AS NZS 3100 To comply with this standard the chlorinator must not be installed in the pool zone Trademarks Throughout this document trademark na...

Reviews: