100-214-276 Rev. 3
7-1
2000X aed Actuator
Chapter 7: Maintenance
Instruction Manual
Calibration
Chapter 7: Maintenance
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-1
Periodic and Preventive Maintenance
- - - - - - - - - - - - - - 7-1
Periodically Clean the Equipment - - - - - - - - - - - - - - - - 7-1
Recondition the Stack (converter, booster, and horn) - - - - - - 7-2
Routine Component Replacement - - - - - - - - - - - - - - - 7-4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-5
7.1 Calibration
This product does not require scheduled calibration. However, if you are operating under
requirements that mandate periodic calibration, for example, the FDA’s Good Manufacturing
Practices, contact your Branson representative for additional information.
7.2 Periodic and Preventive Maintenance
The following preventive measures will help ensure long term operation of your Branson 2000X
Series Actuators.
7.2.1 Periodically Clean the Equipment
Periodically disconnect the unit from power, remove the cover and vacuum out any accumulated
dust and debris. Remove material adhering to the circuit boards, cooling intake vents and
exhaust ports. Periodically disconnect the airline from the air supply, open the air filter and clean
the element and bowl with mild soap and water. External covers may be cleaned with a damp
sponge or cloth using a solution of mild soap and water. Do not allow cleaning solution to enter
the unit. Exposed steel surfaces, such as handles, hardware and the main column may require a
very light film of oil, such as WD-40, to prevent rust in areas of high humidity.