4.11. Calculations on intrinsically safe arrangements
This chapter is a guidance, and nothing but a guidance, on how to demonstrate the intrinsically safety margins of the
installation. The installation engineer, and no one but the installation engineer, is responsible for the intrinsically safety
of the installation. No responsibility is given for the data below. Correct data is printed on the actual included apparatus
or its certificate.
The Zener barriers, ZBs, in the Converting Unit are arranged in order to supply 5 separate intrinsically safe circuits,
ISC. The following data applies to zone IIC.
Table of entity parameters
Parameter
Circuit F2
Circuit F1
Circuit P
Circuit D
Circuit MC
Co
90nF/80nF
90nF/80nF
90nF/80nF
2.5μF
2.5μF
Lo
3mH/1.4mH
3mH/1.4mH
3mH/1.4mH
3mH
0.9mH
Uo
26V
26V
26V
8.41V
8.41V
Io
81mA
81mA
81mA
59.6mA
193.1mA
Po
0.53W
0.53W
0.53W
0.187W
0.41W
ISF2/F1 Intrinsically safe Flow meter.
•
Values below from Fuji flow meter, type FCX-AIII or FCX-AII. See chapter
page
ISP
Intrinsically safe Pressure transmitter.
•
Values below from Siemens type /MF156x.
ISD
Intrinsically safe mechanical switch.
•
Values below from an unspecified type.
ISMC Intrinsically safe Measuring Cell
•
Values below from Measuring Cell type CTB11.
Note: The values for ISF2/F1, ISP and ISD depends on the actual apparatus.
Parameter
ISF2
ISF1
ISP
ISD
ISMC
Ci
26nF
26nF
0nF
0nF
2μF
Li
0.6mH
0.6mH
0mH
0mH
0.165mH
Ui
28V
28V
30V
28V
8.41V
Ii
94.3mA
94.3mA
100mA
100mA
193.1mA
Pi
0.66W
0.66W
0.750W
----
0.41W
Any apparatus should relate to the supplying zener barrier circuit in the following way:
Pi ≥ Po
Ui ≥ Uo
Ii ≥ Io
Co – Ci = Cm
Lo – Li = Lm
Below follows Cm and Lm margins based on the circuit and apparatus data below:
Parameter
Circuit F2/ISF2
Circuit F1/ISF1
Circuit P/ISP
Circuit D/ISD
CircuitMC/ISMC
Cm
54nF
54nF
80nF
2.5μF
0.5μF
Lm
0.8mH
0.8mH
1.4mH
3mH
0,735mH
Ccable
200pF/m
200pF/m
200pF/m
200pF/m
200pF/m
Lcable
1μH/m
1μH/m
1μH/m
1μH/m
1μH/m
The Ccable and Lcable are typical values given in EN_60079-14, calculation for the actual cable in use shall be made.
Maximum cable length for Circuit F/ISF is 270m.
•
If wiring is both in cable Cb3 and Cb7, values for actual length in both cables must be added.
Maximum cable length for Circuit P/ISP is 400m.
Maximum cable length for Circuit D/ISD is 3000m.
Maximum cable length for Circuit MC/ISMC is 735m.
•
The maximum tested length of this cable, Cb7, is 100m.
Also check the temperature class of installed intrinsically safe apparatus and if the specified zone is acceptable.
Concerning cables to intrinsically safe equipment the writing in the standard, IEC 60079-14, is:
Summary of Contents for CleanTrack 1000 B
Page 26: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 26 of 232 ...
Page 27: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 27 of 232 ...
Page 28: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 28 of 232 ...
Page 29: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 29 of 232 ...
Page 31: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 31 of 232 ...
Page 32: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 32 of 232 ...
Page 113: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 113 of 232 ...
Page 120: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 120 of 232 ...
Page 122: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 122 of 232 ...
Page 123: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 123 of 232 ...
Page 149: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 149 of 232 ...
Page 150: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 150 of 232 11 2 Type Approval DNV ...
Page 151: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 151 of 232 ...
Page 152: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 152 of 232 ...
Page 153: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 153 of 232 ...
Page 155: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 155 of 232 ...
Page 156: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 156 of 232 ...
Page 157: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 157 of 232 ...
Page 159: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 159 of 232 ...
Page 160: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 160 of 232 11 5 Type Approval CCS ...
Page 161: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 161 of 232 ...
Page 162: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 162 of 232 ...
Page 163: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 163 of 232 11 6 Type Approval NK ...
Page 164: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 164 of 232 11 7 Type Approval RMRS ...
Page 165: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 165 of 232 ...
Page 167: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 167 of 232 ...
Page 168: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 168 of 232 ...
Page 170: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 170 of 232 ...
Page 171: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 171 of 232 ...
Page 172: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 172 of 232 ...
Page 173: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 173 of 232 ...
Page 175: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 175 of 232 ...
Page 176: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 176 of 232 ...
Page 177: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 177 of 232 ...
Page 179: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 179 of 232 ...
Page 180: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 180 of 232 ...
Page 181: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 181 of 232 ...
Page 182: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 182 of 232 ...
Page 183: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 183 of 232 ...
Page 184: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 184 of 232 ...
Page 186: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 186 of 232 ...
Page 187: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 187 of 232 12 5 2 ATEX Certificate ...
Page 188: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 188 of 232 ...
Page 189: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 189 of 232 ...
Page 190: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 190 of 232 12 6 Flow meter Siemens ...
Page 191: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 191 of 232 ...
Page 192: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 192 of 232 ...
Page 193: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 193 of 232 ...
Page 194: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 194 of 232 ...
Page 195: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 195 of 232 ...
Page 196: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 196 of 232 ...
Page 197: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 197 of 232 ...
Page 198: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 198 of 232 12 7 Flow meter Fuji ...
Page 199: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 199 of 232 ...
Page 200: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 200 of 232 ...
Page 202: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 202 of 232 ...
Page 203: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 203 of 232 ...
Page 204: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 204 of 232 ...
Page 206: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 206 of 232 ...
Page 207: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 207 of 232 ...
Page 208: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 208 of 232 ...
Page 210: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 210 of 232 ...
Page 211: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 211 of 232 ...
Page 212: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 212 of 232 ...
Page 213: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 213 of 232 ...
Page 214: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 214 of 232 ...
Page 215: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 215 of 232 ...
Page 216: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 216 of 232 ...
Page 217: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 217 of 232 ...
Page 218: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 218 of 232 ...
Page 219: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 219 of 232 ...
Page 220: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 220 of 232 ...
Page 221: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 221 of 232 ...
Page 222: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 222 of 232 ...
Page 223: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 223 of 232 ...
Page 224: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 224 of 232 ...
Page 225: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 225 of 232 ...
Page 227: ...Brannstrom Sweden AB CleanTrack 1000B Rev 2 20xd 2019 Page 227 of 232 ...