26
H
o w d o y o u i n s
We cannot be held responsible for any accident resulting from an
inexistent, defective or incorrect ground lead.
The electrical connection should be performed before the appliance is installed in
the cabinet.
• The oven must be connected with a power cable (standardized) with three 1.5 mm²
conductors (1 ph +1 N + ground
) that must be connected to a
monophase 220–240 V network via a CEI 83 standardized receptacle (1 ph +1 N +
ground lead
) or in accordance with installation rules. The safety wire (green-
yellow) is connected to the appliance's terminal
and must be connected to the
ground lead of the electrical set-up.
• In the case of connections with an electric receptacle, it must remain accessible
after installation of the appliance.
• The oven's neutral conductor (blue wire) must be connected to the network's
neutral conductor.
I
nstallation and/or replacement of power cable
• The power cable (H05 RR-F, H05 RN-F or H05 VV-F) must be of sufficient length to be
connected to the build-in oven while it sits on the floor in front of the cabinet.
To do this the appliance must be disconnected from the electrical network :
• Open the inspection flap located at the lower right of the back cover by unscrewing
the two screws, then pivot the inspection flap.
• Strip 12 mm along each wire of the new power cable.
• Carefully twist together the strands.
• Loosen the screws from the terminal board and remove the power cord to be
replaced.
• Introduce the power cable through the side of the cover in the cable clip located to
the right of the terminal board
• Connect the power cord wires in accordance with the written markings on the
terminal board.
• All the strands of the electricity wires must be captured under the screws.
• The phase wire on the L terminal.
• The green-yellow coloured ground wire should be connected to the terminal
.
• The neutral conductor (blue) on the N terminal.
• Screw down tightly the screws on the terminal board and check the connection by
pulling on each wire.
• Attach the cable with the cable clip located to the right of the terminal board.
• Close the inspection flap using the two screws.
99633691 ML.qxd 02/09/04 09:41 Page 26