42
Printer Applicator System PAM 3600
Service Manual PAM 3600
4 Replacing Assembly Units
Sensors peel-off table
View A
C
A
B
D-A93V
D-A93V
View B
View C
11
12
12
9
10
8
10
Figure 4r Replacing the sensors peel-off table
8 Canal
9 Cable
10 Screw
11 Base plate
12 Sensor peel-off table
Remove label stock and transfer ribbon from the printer.
Remove the cover.
Remove the cable from the cable holder (1).
Remove the plug (5) from the applicator control PCB (3), loosen the screws of the concerning cable and
remove it.
Loosen the screw (do not remove it) on the concerning sensor (12) and remove the sensor.
Pull out the cable with the sensor.
Therefore loosen (not remove) the two screws (10) on the base plate (11) below the peel-off table.
Now it is possible to move the cylinder above the base plate to push the sensor with the cable (9) through the
canal (8) and the mounting plate to the rear side.
Replace the sensor and reassemble in reverse order.
NOTICE!
Pay attention before tighten the two screws (10):
Put the cable carefully in the canal (8) and click the holes of the cylinder into the positioning
pins at the base plate.
8. Connect the printer to the power supply, switch on printer and compressed air.
9. Check the replaced sensor of correct adjusting and adjust it if necessary (see section 5.4).
1.
2.
3.
4.
5.
6.
7.
Summary of Contents for PAM 3600
Page 1: ...Printer Applicator System PAM 3600 Service Manual Edition 1 07...
Page 74: ...A 2 Printer Applicator System PAM 3600 Service Manual PAM 3600 Appendix A Block Diagram...
Page 88: ...B 14 Printer Applicator System PAM 3600 Service Manual PAM 3600 Appendix B Circuit Diagrams...
Page 94: ...C 6 Printer Applicator System PAM 3600 Service Manual PAM 3600 Appendix C Layout Diagrams...