25
Printer Applicator System PAM 3600
Service Manual PAM 3600
3 Maintenance
3.5
Cleaning the Pad
During operation, dust particles accumulate on the pad. It is recommended to clean the pad regularly.
WARNING!
Mortal danger by electric shock!
Disconnect power supply!
Switch off compressed air!
1
2
Figure 3d Cleaning the pad
1 Valve
2 Pad
Slightly pull the valve (1) until the bleed position is reached. So it is possible to move the pad manually.
Slide the pad (2) to a position where the underside of the pad is easily accessible.
Clean the underside of the pad.
Remove particles with a soft brush or a vacuum cleaner.
Remove label fragments and traces of adhesive with alcohol if necessary.
The suction holes on the underside of the pad must be free.
Perform a visual check of the pad (2) and the slide foil on the underside of the pad. If the slide foil is damaged,
it must be replaced.
NOTICE!
Slide the valve (1) back to the operate position!