Installation

 

Bradmar

 Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400

Bradley 

• 

HDWP-INSTR-013 Rev. K; ECN 12-14-012

 

10/1/2014

*

*

*

*

*

*

*

*

*

Pilaster 

Plumb Line

When installing the partition components, consult 

the applicable Mills Partition submittal drawing 

for compartment layout dimensions.

1a Layout Dimensions - Stirrup Brackets (Optional)

Pilaster Shoe Centerline:

  Measure from 

the back wall forward to the face of the 

compartment, subtract ½" (13mm) and 

mark this location on the floor (“A”). Mark 

the same measurement on the opposite 

end of your layout (“A1”) and draw a 

straight line connecting both marks.

FOR FREESTANDING (FS) PARTITION:

 

Refer to submittal drawings and determine 

the approximate location of the outside 

panels. Establish dimensions “A” and “A1” 

as explained above.

A

Panel centerline:

  Measure the stall width across the 

back wall and place a mark at the base of the rear wall 

(“B”). Repeat this step for each panel, starting each 

measurement from the last panel centerline (“B1”).

B

Stirrup brackets:

  Draw a plumb line on all walls 

from each pilaster and panel centerline . From the 

highest point in the room, measure 20"(508mm), 

41½"(1054mm) and 63"(1600mm) from the floor 

and place a mark on the pilaster/panel plumb line 

("C"). These marks represent the hole center line 

of the stirrup brackets. Use a level to transfer that 

mark to all other plumb lines.

C

Panel 

plumb line

63" 

(1600mm)

41½" 

(1054mm)

"A"

"B"

"B1"

"A1"

"C"

"C"

"C"

"C"

"C"

"C"

"C"

"C"

"C"

20" 

(508mm)

C

L

C

L

C

L

C

L

C

L

C

L

C

L

CL

CL

CL

Pilaster 

Plumb Line

When installing the partition components, 

consult the applicable Mills Partition submittal 

drawing for compartment layout dimensions.

1

Layout Dimensions - Continuous Brackets (Standard)

Pilaster Shoe Centerline:

  Measure from 

the back wall forward to the face of the 

compartment, subtract ½" (13mm) and 

mark this location on the floor (“A”). Mark 

the same measurement on the opposite 

end of your layout (“A1”) and draw a 

straight line connecting both marks.

FOR FREESTANDING (FS) PARTITION:

 

Refer to submittal drawings and 

determine the approximate location of the 

outside panels. Establish dimensions “A” 

and “A1” as explained above.

A

Panel centerline: 

 Measure the stall width across the 

back wall and place a mark at the base of the rear wall 

(“B”). Repeat this step for each panel, starting each 

measurement from the last panel centerline (“B1”).

B

Continuous brackets: 

 Draw a plumb line on all walls from each 

pilaster and panel centerline . From the highest point in the room, 

measure 14½" (369mm) from the floor and place a mark on the 

pilaster/panel plumb line. Use a level to transfer that mark to all 

other plumb lines (“C”).

C

Panel 

plumb 

line

"C"

"C"

"C"

"A"

"B"

"B1"

"A1"

*

*

*

14½" (369mm) To 

bottom of bracket 

(highest point in 

floor)

Summary of Contents for Bradmar 400 Series

Page 1: ...enance department Compliance and conformity to local codes and ordinances is the responsibility of the installer Separate parts from packaging and make sure all parts are accounted for before discardi...

Page 2: ...ar saw Two spring clamps and drill bits Power drill or screw gun with drill bit extension Tape measure and 4 level ceramic tile and masonry drill bit Hammer drill Spacer 14 356mm high and strong enoug...

Page 3: ...present the hole center line of the stirrup brackets Use a level to transfer that mark to all other plumb lines C Panel plumb line 63 1600mm 41 1054mm A B B1 A1 C C C C C C C C C 20 508mm C L C L C L...

Page 4: ...Remove the bracket and drill a hole min 2 51mm deep at each hole location B One Eared Bracket Two Eared Bracket 2 Continuous Brackets to Wall Standard established level line pilaster panel plumb line...

Page 5: ...Measure down from the top of the pilaster and place a mark on the pilaster split centerline at dimensions at 13 343mm and 67 1715mm Pilaster shown is for reference only Actual pilaster varies dependi...

Page 6: ...Split A B C U Bracket H Bracket Dim A 19 483mm 13 343mm Dim B 40 1029mm 67 1715mm Dim C 62 1575mm Secure the stirrup brackets to the pilasters using the 14 x screws provided Refer to step 4 for locat...

Page 7: ...13mm between the panel and pilaster Using the bracket as a template drill holes through the pilaster at each pilaster bracket hole Secure the pilaster to the bracket with 10 24 x barrel nuts and 10 24...

Page 8: ...m between the panel and pilaster Using the brackets as a template drill holes through the pilaster at each pilaster bracket hole Secure the pilaster to the bracket with 10 24 x barrel nuts and 10 24 x...

Page 9: ...spacing between the pilasters for the doors is the correct dimension On the back of each pilaster starting with the first pilaster drill a hole through one face of the headrail only Using this hole as...

Page 10: ...rt the spring and the top pin into the pilaster top Move the top of the door into position while pushing the top pin into the pilaster Release the top pin and force the pin to bottom out in the door C...

Page 11: ...3 Top Pin Lip Lip 3 76mm 3 Top Pintle 3 Bottom Pintle Assembly Notch Feature for adjacent door strike 19mm 1 44mm 13mm Drill first hole as shown Attach and align heat sink with single screw 6 x flat h...

Page 12: ...a 8 x 1 flat head Phillips drive screw To adjust spring tension use a torx screwdriver and turn the torx head clockwise approximately one complete revolution Insert a 1 38mm long nail into the hole th...

Page 13: ...d to the shoe and that the headrail is installed Determine the door swing by facing the compartment from the outside Refer to your submittal drawings to determine each specific door swing for your app...

Page 14: ...or Use tape to hold the hinge sets together H Place the upper blank of the top hinge set on the door 2 51mm from the top Using the hinge as a template drill a x 1 25mm deep pilot hole into the edge of...

Page 15: ...the door so that the slide bar is centered in the slot on the strike keeper The leading edge of the latch should be positioned approximately 10mm from the door edge Install the coat hook in the upper...

Page 16: ...so that the slide bar is centered on the strike keeper The leading edge of the latch should be positioned approximately 1 25mm from the door edge Install the coat hook according to local codes For su...

Page 17: ...as a template drill a pilot hole into the door 19mm deep Secure the latch to the door using hardware provided B With the door in the closed position mount the latch on the inside of the door so that...

Page 18: ...A B G F H With the door in the closed position mount the latch on the inside of the door so that the center of the slide bar is 27 699mm from the top of the door The leading edge of the latch should b...

Page 19: ...16 and larger B Using the bracket as a guide drill a x deep pilot hole at each screw hole location The stiffener bracket is installed on the largest side of a pilaster split B Using the bracket as a g...

Page 20: ...hole locations on the wall Remove the bracket and drill a x min 2 51mm deep hole at each hole location C Place the bottom of the continuous bracket at the established level line Center the bracket ope...

Page 21: ...e hole locations on the wall Remove the bracket and drill a x min 2 51mm deep hole at each hole location B Place the bottom of each urinal screen 18 457mm up from floor Establish a 1 25mm gap between...

Reviews: