3
Installation
Bradmar
™
Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
Bradley
•
HDWP-INSTR-013 Rev. K; ECN 12-14-012
10/1/2014
*
*
*
*
*
*
*
*
*
Pilaster
Plumb Line
When installing the partition components, consult
the applicable Mills Partition submittal drawing
for compartment layout dimensions.
1a Layout Dimensions - Stirrup Brackets (Optional)
Pilaster Shoe Centerline:
Measure from
the back wall forward to the face of the
compartment, subtract ½" (13mm) and
mark this location on the floor (“A”). Mark
the same measurement on the opposite
end of your layout (“A1”) and draw a
straight line connecting both marks.
FOR FREESTANDING (FS) PARTITION:
Refer to submittal drawings and determine
the approximate location of the outside
panels. Establish dimensions “A” and “A1”
as explained above.
A
Panel centerline:
Measure the stall width across the
back wall and place a mark at the base of the rear wall
(“B”). Repeat this step for each panel, starting each
measurement from the last panel centerline (“B1”).
B
Stirrup brackets:
Draw a plumb line on all walls
from each pilaster and panel centerline . From the
highest point in the room, measure 20"(508mm),
41½"(1054mm) and 63"(1600mm) from the floor
and place a mark on the pilaster/panel plumb line
("C"). These marks represent the hole center line
of the stirrup brackets. Use a level to transfer that
mark to all other plumb lines.
C
Panel
plumb line
63"
(1600mm)
41½"
(1054mm)
"A"
"B"
"B1"
"A1"
"C"
"C"
"C"
"C"
"C"
"C"
"C"
"C"
"C"
20"
(508mm)
C
L
C
L
C
L
C
L
C
L
C
L
C
L
CL
CL
CL
Pilaster
Plumb Line
When installing the partition components,
consult the applicable Mills Partition submittal
drawing for compartment layout dimensions.
1
Layout Dimensions - Continuous Brackets (Standard)
Pilaster Shoe Centerline:
Measure from
the back wall forward to the face of the
compartment, subtract ½" (13mm) and
mark this location on the floor (“A”). Mark
the same measurement on the opposite
end of your layout (“A1”) and draw a
straight line connecting both marks.
FOR FREESTANDING (FS) PARTITION:
Refer to submittal drawings and
determine the approximate location of the
outside panels. Establish dimensions “A”
and “A1” as explained above.
A
Panel centerline:
Measure the stall width across the
back wall and place a mark at the base of the rear wall
(“B”). Repeat this step for each panel, starting each
measurement from the last panel centerline (“B1”).
B
Continuous brackets:
Draw a plumb line on all walls from each
pilaster and panel centerline . From the highest point in the room,
measure 14½" (369mm) from the floor and place a mark on the
pilaster/panel plumb line. Use a level to transfer that mark to all
other plumb lines (“C”).
C
Panel
plumb
line
"C"
"C"
"C"
"A"
"B"
"B1"
"A1"
*
*
*
14½" (369mm) To
bottom of bracket
(highest point in
floor)