background image

Page 23

UG_RGW_v1.12_EN

Q. 

Will the chlorine tablets cause problems with my septic tank?

 

A. 

Considering the concentration of chlorine in the volumes of water involved, the chlorine in your 

grey water shouldn't cause any problems in a modern, healthy septic system.

While we haven't had any reports of problems, there could be issues with older, smaller septic sys-

tems that are already operating on the edge of failure.

In such cases, there are a variety of products available, such as "Septic Miracle" and "Organica 

Cesspool/Septic Treatment", to name two, that can help boost the bacterial culture of a struggling 

septic system.

Consult with a waste professional if you have concerns about your septic system.

Not using tablets at all is not recommended, as unpleasant odors will almost certainly result after a 

few weeks.

Q. 

How hard is it to install a BRAC System?

 

A. 

While the connections are not difficult, a qualified professional plumber should only install your 

BRAC System. In new construction, it is easy to design the system into the plumbing of the home. 

In an existing home, new water supply lines for the toilets will need to be installed, and some of your 

drains will need to be rerouted.

You should consult a plumber for an evaluation of your existing construction to determine the feasi-

bility/difficulty of installing a BRAC System in your particular situation.

Q. 

What happens in the event of an extended power outage, or if my BRAC System 

needs to be removed for some reason? 

A. 

When your plumber installs your BRAC System, he should install a fresh water bypass with ball 

and check valves between the fresh water supply and the grey water outlet lines. This will allow you 

to easily supply your toilets with fresh water (and prevent the contamination of your fresh water with 

grey water) in the event of an extended power outage or removal of the tank. If the tank must be 

removed, a drain pipe can be easily fitted between where the grey water inlet and over flow drain 

entered the tank, diverting your bath water to the sewer.

Q. 

Is a basement necessary to use the BRAC System?

 

A. 

Not necessarily. The transportation of grey water to your BRAC System is by gravity, so as long 

as the bathtub/shower/laundry drains are above the inlet of the filter housing, the system will func-

tion. For those who have a single-level home on a slab foundation, or who wish to utilize the BRAC 

System in a "flat", BRAC Systems offers a Sump and Pump kit (BSP kit), which consists of a sump 

basin and fully submersible sump pump. The basin is installed in the foundation or floor to collect 

grey water from bathing fixtures and the sump pump automatically pumps the grey water up to the 

level of the BRAC System inlet.

Q. 

You state that use of laundry water in the BRAC System is optional if allowed in 

your jurisdiction. What issues should I be aware of when considering this option? 

A. 

Based upon customer usage, we have found that on average, if every member of a household 

bathes once per day, the amount of grey water generated nearly matches the amount of water used 

to flush the toilets in that household. In addition, laundry water contains a great deal of lint, which 

will clog your filter quicker, requiring more frequent filter cleaning. So you should balance your fam-

ily's bathing habits against the increased maintenance that will be required. Since the drain hose of 

a laundry machine can be easily moved, you may even consider having both a traditional sewage 

drain and a grey water drain behind your laundry machine, so that you can switch back and forth as 

your needs and convenience dictate.

Summary of Contents for RGW-150

Page 1: ...INSTALLATION MANUAL AND USER GUIDE RGW 150 RGW 250 RGW 350 RGW 450 V1 12 UG_RGW_v1 12_EN June 7 2010 9 16 AM BRAC SYSTEMS GREY WATER RECYCLING Residential Series...

Page 2: ...E INSTALLA TION CHECKLIST SUPPLIED WITH THIS MANUAL The content of this guide is based upon the latest information available at the time of printing and is aimed at providing a general introduction to...

Page 3: ...6 0 Installation Kit 8 7 0 Preparation 9 8 0 Installation 10 9 0 System Connections 11 10 0 Priming and Start Up 12 11 0 BC 100 Controller 13 12 0 Pump Manual 14 13 0 Technical Data 15 14 0 Maintenanc...

Page 4: ...lowing the grey water to be treated to a safe level without becoming over chlorinated The RGW series requires a connection to your home s sanitary drain and should only be installed by a licensed plum...

Page 5: ...njury read all the instructions before using this unit This system is intended for household use only as described in this manual Any other use including but not limited to commercial agricultural or...

Page 6: ...Page 6 UG_RGW_v1 12_EN 3 0 Safety Components Figure 1 Backwater Valve Figure 2 Non Contamination System SWING CHECK VALVE OVERFLOW 3 PIPE FROM RGW OVERFLOW PIPE TO SEWER SYSTEM TO SEWER SYSTEM...

Page 7: ...r Grey Water Suction Unit Grey Water Suction Foot Valve Unit Air Gap Fresh Water Chlorinator www bracsystems com Brac Grey Water Controller BC 100 Enabled Integrated Water Processing 4 0 System Compon...

Page 8: ...ss connection control 4 device if required by local codes and freshwater bypass line A grey water supply connection to toilets 5 A 1 clean out drain valve supplied connect to the sewer line if require...

Page 9: ...valve on one end and a grey PVC elbow with a stainless steel flange attached at the other end Remove two bolts and rubber gasket from the side of the pump Fill the pipe with approximately 2 liters 5 g...

Page 10: ...l prevent the loss of grey water through the bypass during normal operation See figure 5 Install a P Trap and an approved backwater valve such as a swing check valve down stream 4 of the overflow port...

Page 11: ...vice prevents contamination in the event of a sewage back up The cross connection control device prevents contamination of the potable water system The freshwater bypass valve provides water to toilet...

Page 12: ...ff valve Plug in the pump s AC power cord The pump should begin drawing water and pressurizing the 4 service lines Once the pump is primed and the grey water OUT line is pressurized it will take 8 sec...

Page 13: ...ing cycles at more convenient times for the household The enabled LED should be green to show that the system is operational If the LED flashes this indicates that water level sensor has not been conn...

Page 14: ...2 Maintenance Under normal operating conditions the pump does not require any maintenance as long as the fol lowing points are observed 1 Periodically check the condition of the check valve located un...

Page 15: ...5 8 4 5 3 2 2 0 6 250 350 450 10 22 5 22 1 21 7 21 3 20 8 20 5 67 20 20 7 20 2 19 8 19 2 18 8 18 2 30 18 3 17 8 17 1 16 2 15 3 14 2 40 14 7 13 8 12 9 12 1 11 1 10 2 50 10 5 9 3 8 1 6 9 5 6 4 3 RGW Mo...

Page 16: ...140 gram 5oz tablets Replace the chlorinator lid and tighten se curely We recommend that the NORWECO brand Bio Sanitizer Calcium Hypochlorite disinfecting tablets be used Some jurisdictions require t...

Page 17: ...cap Replace the filter back into the filter housings and replace the screw cap Replace the RGW system lid 13 Close the potable bypass valve if applicable 14 Open the grey water bypass valve if applic...

Page 18: ...f the strainer screen is clean no further action is necessary and the flange can be replaced onto the pump and the two bolts inserted and tightened Remove the gasket from the flange and take out the s...

Page 19: ...ve the black screw cap on the filter housing and remove the filter See figure 6 8 Pour a minimum of five liters of household vinegar through the filter housing and leave for fifteen 9 minutes Apply a...

Page 20: ...reuse grey water A Yes when first disinfected and used in an appropriate way Grey water can contain disease causing micro organisms such as bacteria protozoa viruses and parasites It may also contain...

Page 21: ...nisms to survive and cause infection is considered remote Grey water from the bathroom is suitable for reuse Laundry A Check local plumbing codes If the laundry option is allowed in your jurisdiction...

Page 22: ...w can I improve grey water quality by using different types of soaps or deter gents A The choice of cleaning products can reduce the environmental impact of grey water Common washing powders contain s...

Page 23: ...ply your toilets with fresh water and prevent the contamination of your fresh water with grey water in the event of an extended power outage or removal of the tank If the tank must be removed a drain...

Page 24: ...eset activation pump otherwise the pump will not start Q What is the maximum pressures switch activation point A Adjust the pressure only when the cut in pressure is higher than the preset activation...

Page 25: ...ks and repair 2 Defective check valve or suction foot valve Inspect and clean check valve and or foot valve Replace if necessary Pump starts and stops too frequently 1 Leakage in suction foot valve pi...

Page 26: ...and the system can be re primed Refer to chapter 10 0 Priming and Start up 2 Pump has lost it s prime Re prime pump Refer to chapter 10 0 Priming and Start up Lower tank is full and draining out of o...

Page 27: ...l Non conformity of local plumbing codes Connection to an improper source or for improper use Misuse abuse negligence physical damage or accidents Improper service and or maintenance Repair changes or...

Page 28: ..._________________ IMPORTANT To activate your warranty and register your product please complete the Product Registration and Installation Check List form supplied with this system and mail to BRAC Sys...

Reviews: