background image

- Intercom calls (max. 8) with VSE/301 selector or for
activating auxiliary services with actuators.
- Call transfer in intercom mode.
- Light signal with doubling LED to indicate system
busy.

If there is a call from the entry panel during a conver-
sation between intercom sets, a short audible signal
repeated every 5 s advises the receiver’s user of the
call. By pressing one of the call buttons and pressing

, the conversation can be transferred to another

receiver.
The receiver receiving the transferred call can, in turn,
transfer the call.

STANDARD PROGRAMMING

(without using relevant programmers)

To programme the call in system 300 or X1 (X2) instal-
lations, see the literature enclosed with the XA/300LR
control unit and X2 entry panel.
To program call buttons 2 and 3, where necessary,
simply press the corresponding keys following the first
call button once you have entered receiver program-
ming mode.

NOTE. Do not exit receiver programming mode until
you have associated all the desired calls.

To programme intercom calls, see the instructions
provided with the VSE/301 selector.

PROGRAMMING WITH MPP/300LR 
OR PCS/300

The unit can be programmed through the
MPP/300LR unit using the dedicated profile for the
XC/310 receiver, or by means of PCS/300 by selec-
ting the corresponding receiver (OPHERA).

Programming melodies and number of rings

To enter programming mode, press the button 

5

times, within 5 s.

A short audible signal sounds to confirm you have
entered programming mode (you automatically enter
the entry panel call melody programming procedure).

Press the door lock release button 

to run through

the different modes in sequence.
A number of short audible signals sound to indicate
that you have entered the corresponding mode:

A - 1 audible signal:

programming of melody asso-

ciated with the call from the entry panel.

B - 2 audible signals:

programming of melody asso-

ciated with doorbell.

C - 3  audible  signals:

programming of number of

rings announcing a call from the entry panel.

A - Programming of melody associated with the call
from the entry panel

The first entry panel call melody is played repeatedly,
alternated with a short audible signal. 
To listen to the next melody, press the auxiliary button
2 (

) (

in the OPHERA/B model) during the pause

between the audible signal and melody.
Repeat the operation until you hear the melody you
want.
To save the new setting without programming
anything else, press the button 

; or press the

door lock release button 

to access the next pro-

gramming procedure.

B - Programming of melody associated with door-
bell

The first doorbell melody is played repeatedly, alter-
nated with two short audible signals.
To listen to the next melody, press the auxiliary button
2 (

) (

in the OPHERA/B model) during the pause

between the audible signal and melody.
Repeat the operation until you hear the melody you
want.
To save the new setting without programming
anything else, press the button 

; or press the

door lock release button 

to access the next pro-

gramming procedure.

C - Programming of number of rings announcing a
call

Three short audible signals sound. 
Decide how many rings you want and press the auxi-
liary button 2 (

) (

in the OPHERA/B model) the

corresponding number of times (in the range 1 to 6).

In system 300 installations, you can increase the
number of rings to a maximum of 51 by customizing
control unit XA/300LR.

3 s after the button was last pressed, you will hear the
call selected for the chosen number of rings.
If you want to save settings without programming
anything else, press the button 

; or press the

the entry panel activation button

. Press again to

switch between entry panels.

Alarm

The alarm is sent each time any remote device con-
nected to the AL input of the M1 terminal block is acti-
vated.
This warning takes priority over all the others. 
The command is handled through the actual porter
switchboard (the message Alarm and the user's num-
ber come up on the display). 

Privacy (in the OPHERA/B model only)

This function is active only with the video handset sta-
tion off.
The user can press the Mute/Privacy 

button to iso-

late the receiver from all calls sent to it, the LED light.
When making a call to the receiver, the porter receives
the Privacy status warning. 
Press the same button again to exit Privacy status,
the LED goes off.

Porter call

By pressing the Porter call button 

(

in the

OPHERA model where installed) a call is made by the
user to the porter switchboard.
Should the porter call the user and the user fail to
answer, the LED on the receiver comes on if the por-
ter leaves a message. 
Once the user manages to speak with the porter, the
LED goes off.  

Panic (in the OPHERA/B model only)

By pressing the Panic button 

the panic status is

sent to the porter switchboard (the message Panic
and the user's number come up on the display).
The red LED comes on to confirm receipt by the por-
ter.  This LED goes off when the porter calls the user.
This warning takes priority over all the others.

Calibrating the audio levels

- Activate the receivers 

and select the talk-listen

operating mode.
- Adjust the volumes on the entry panel in the talk-
listen mode.
-  Go to the hands-free mode 

(

in the OPHE-

RA/B model) and check the regularity of switching
from one channel to another.
-  If there is difficulty in getting the line in one of the two
directions, increase the volume slightly in the direction
where you have difficulty and reduce it in the other
direction.
In combined systems (receivers and hands-free) we
recommend you first adjust the communication levels
for the hands-free system.
If necessary, adjust the volumes on the entry panel to
achieve a better compromise.

Function of jumper SW1
(Resistive load termination)

The unit features a jumper 

SW1

(fig. 8) for the imped-

ance terminating the signal line. Remove the jumper if
the line continues towards other video handsets.

Function of jumper SW2
(Selects power source)

The video handset has a jumper 

SW2

(fig. 8) for selec-

ting the type of power supply (from BUS or a separa-
te power supply unit). 
For power supply from X1 BUS 

(max. 1 video hand-

set active only)

, position jumper 

SW2

on 

BUS

(default setting). 
For separate power supply, position jumper 

SW2

on

LOCAL

(as additional receiver for a simultaneous call

or use in X2 installations).

OPHERA AND OPHERA/B HANDS-FREE 
INTERCOMMUNICATING COLOUR 
VIDEO HANDSET

The button accessory provided lets the video handset
change to an intercommunicating appliance.
It features the following controls (fig. 4):

1÷4(5÷8)

Call buttons

Doubling button (for calls 5÷8) 
(red LED)

To apply the button accessory, remove the left cover
and unscrew the two screws (fig. 5). 
Insert the intercommunicating accessory, tighten the
two screws and insert the cover (fig. 6-7). 
This accessory allows the basic functions for the
video handset to be used: 

2

1 - 5

2 - 6

3 - 7

4 - 8

>

4

OPHERA

2

5

OPHERA

1 - 5

2 - 6

3 - 7

6

OPHERA

7

Summary of Contents for OPHERAKIT/**US

Page 1: ...ess the button to initiate communication the LED light Press down the button in the OPHERA B model to speak with the entry panel Release the button in the OPHERA B model to listen the LED light To end communication press the button the LED goes off Entry panel selection in installations with a num ber of entry panels With the system off turn on the monitor by pressing 24800401 12 03 10 OPHERAKIT U...

Page 2: ...f 51 by customizing control unit XA 300LR 3 s after the button was last pressed you will hear the call selected for the chosen number of rings If you want to save settings without programming anything else press the button or press the the entry panel activation button Press again to switch between entry panels Alarm The alarm is sent each time any remote device con nected to the AL input of the M...

Page 3: ...pin CN3 connector used for connection to buttons KHPS or KHPD 1 red to button n 2 2 orange to button n 3 3 yellow to button n 4 WARNING In installations with a number of entry panels call buttons must be arranged in the same order on each Connector CN4 comes ready connected 1 black to button no 1 2 brown to button no 1 3 green to LEDs lighting the buttons 4 yellow to LEDs lighting the buttons 2 pi...

Page 4: ...in fig 22 Replace the covers The appliance is equipped with 3 sets of exchangea ble covers in different colours To replace proceed as shown in fig 20 and 22 Video entry panel HEV 301 HEVC 301 The embedding box must be fitted flush with the wall and at an height that ensure optimal camera opera tion Fit the spacer into embedding boxes to avoid deformation fig 23 It is possible to use the screwdrive...

Page 5: ...ias entradas Con el equipo apagado pulsar el botón de activa ción de la placa exterior para encender el moni tor y volverlo a pulsar para seleccionar las placas exteriores Alarma La alarma se envía cada vez que un dispositivo remo to cualquiera conectado a la entrada AL de la borne ra M1 se activa Esta señalación tiene prioridad sobre todas las demás El comando es administrado por la propia conser...

Page 6: ...pro gramaciones pulsar el botón sino pulsar el botón abrepuerta para entrar en la programación siguiente B Programación de la melodía asociada con la lla mada desde el rellano Se oye varias veces la melodía n 1 de la llamada desde el rellano alternada con dos señales acústicas breves Para escuchar la melodía siguiente pulsar el botón auxiliar 2 en el modelo OPHERA B durante la pausa entre la señal...

Page 7: ...s derivados internos 6 Conectar de nuevo el puente SW2 para salir de la programación ATENCIÓN El procedimento de programación del selector VSE 301 si presente debe ser efec tuado sólo después de la programación de la asociación de las llamadas desde las placas externas con los derivados internos En las instalaciones con XA 300LR se recomien da recoger los códigos de identificación ID SN de los der...

Page 8: ...e bloqueo y desmontar la placa de la base fig 24 Para montar ulteriores pulsadores es preciso seguir las instrucciones que los acompañan Quitar las dos cubiertas protectoras de los agujeros roscados en la caja de empotrar y asegurar el basti dor con los dos tornillos incluidos en el suministro fig 25 Efectuar las conexiones Para escribir los datos que se desea en el letrerito de identificación ret...

Page 9: ...9 29 30 ...

Page 10: ...KHPD KHSO HEP 306 HEP 312D B IN B OUT 2 R 34 A G VAS 100 1 2 1 2 HEV 301 HEVC 301 HET 301 B IN B OUT NC C NO C M1 AC 200 5 6 21 7 14 SW1 L N 32 B VLS 101 A 1 2 3 A G VAS 100 1 2 1 2 HEV 301 HEVC 301 HET 301 B IN B OUT 1 2 3 4 5 L N 31 Fig 31 Sample connection of Aux 1 or Aux 2 auxiliary output with relay unit VLS 101 Power supply by means of VAS 100 Fig 31 Ejemplo de conexión salida auxiliar Aux 1...

Page 11: ...t can also be used individually to realize multi family installations Cross section of cables see entry panel instructions ATENCION Los aparatos que componen este kit pue den ser utilizados individualmente para realizar instalaciones multifamiliares Para la sección de los conductores ver las instrucciones de la placa exterior CP Personal door bell button Pulsador de llamada desde el rellano ...

Page 12: ...12 ...

Reviews: