5.3.3.2 OPTIONS > PROFILES TAB
Monitor Profile:
Selects the profile (PPM and Rate and Ratio) expected when milking. Up to 5 profiles can be selected.
Using profiles allows using different PPM’s and Rate/Ratio during operation. For example, to have a different PPM or
Rate/Ratio when washing compared to milking.
Washing Profile:
Selects the profile (PPM and Rate and Ratio) expected when washing.
Stimulation Profile:
Selects the profile (PPM and Rate and Ratio) expected when doing stimulation.
Stimulation Mode:
• Selects the stimulation mode. (Used only when performing pulsation. This has no effect if monitoring only.)
• All time: Stimulation is performed a fixed amount of time (default setting).
• First Milk: Stimulation is performed until milk starts to flow (requires SmartLite system).
• User Button:
Stimulation Performed until user presses the attach button again (requires SmartLite system).
Stimulation Pre-delay:
Amount of seconds to wait for stimulation to start.
Stimulation Duration:
Total amount of seconds for stimulation.
5.3.4 PROFILES BUTTON
There are five possible profiles to setup. The profile number needs to be selected before changing parameters. The
default selection is profile 1.
Profile Pulses:
Pulses Per Minute (PPM) expected for this profile.
Profile Front Rate on:
Rate on percentage for front cow teats.
Profile Rear Rate on:
Rate on percentage for rear cow teats.