Servicing
5
Installation and maintenance instructions for wall-mounted condensing gas boiler 600 - 28C • 01/2004
57
Subject to modifications resulting from technical improvements!
Boulter Buderus Ltd. • http://www.boulter-boilers.com
5.3.12 Replacing the hot surface ignitor
z
Disconnect the boiler from the mains power supply.
z
Disconnect the plug of the hot surface ignitor (fig. 87,
item 1).
z
Disconnect the hot surface ignitor (see fig. 89, item 1).
z
Connect a new hot surface ignitor in reverse order.
5.3.13 Replacing the ionisation electrode
z
Disconnect the boiler from the mains power supply.
z
Disconnect the plug of the ionisation electrode
(see fig. 90).
z
Remove the ionisation electrode (see fig. 91, item 1).
fig. 89 Replacing the hot surface ignitor
1
CAUTION
Be careful, the hot surface ignitor is made of a
fragile material and can be damaged easily.
fig. 90 Disconnecting plug
fig. 91 Remove ionisation electrode
1