MENU
27
Knob
Parameter
Value
Explanation
Page 3
[1]
ACT .LO
(ACT RANGE LO)
0–126
You can set the controllable range
for target parameters within the
source’s operational range. Target
parameters are controlled within
the range set with ACT LO and
ACT HI. You should normally set
ACT LO to 0 and ACT HI to 127.
[2]
ACT .HI
(ACT RANGE HI)
1–127
[3]
WAV .RT
(WAVE RATE)
*1
0–100,
BPM –
This determines the time spend
for one cycle of the assumed EXP
Pedal.
When set to BPM, the value of each parameter will
be set according to the value of the “MASTER BPM”
specified for each patch. This makes it easier to
achieve effect sound settings that match the tempo
of the song.
* If, due to the tempo, the time is longer than the
range of allowable settings, it is then synchronized
to a period either 1/2 or 1/4 of that time.
[4]
WAV .FM
(WAVE FORM)
*1
SAW
TRI
SINE
Page 4
[1]
TRIGGER
(INT PEDAL
TRIGGER)
*2
PAT CNG
(PATCH CHANGE)
This is activated when a patch is
selected.
EXP LO
This is activated when an external
expression pedal connected to
the CTL/EXP jack is set to the
minimum position.
EXP MID
This is activated when the
external expression pedal
connected to the CTL/EXP jack
is moved through the middle
position.
EXP HI
This is activated when the
external expression pedal
connected to the CTL/EXP jack is
set to the maximum position.
CTL1 PDL
This is activated when an external
footswitch connected to the CTL/
EXP jack is operated.
CTL2 PDL
This is activated when an external
footswitch connected to the CTL/
EXP jack is operated.
CC#1–#31
This is activated when a control
change is received.
CC#64–#95
This is activated when a control
change is received.
[2]
TIME
(INT PEDAL TIME)
*2
0–100
This specifies the time over which
the internal pedal will move from
the toe-raised position to the
toe-down position.
[3]
CURVE
(INT PEDAL
CURVE)
*2
LINEAR
SLOW
(SLOW RISE)
FAST
(FAST RISE)
*1 The WAVE RT and WAVE FM parameters are enabled when the Source parameter
is set to WAVE PDL.
*2 The TRIGGER, TIME, and CURVE parameters are enabled when the SOURCE
parameter is set to INT PEDAL.