52
Environment / disposal
Sense II – 6 720 818 367 (2015/10)
9
Environment / disposal
Environmental protection is a fundamental corporate strategy
of the Bosch Group.
The quality of our products, their efficiency and environmental
safety are all of equal importance to us and all environmental
protection legislation and regulations are strictly observed.
We use the best possible technology and materials for
protecting the environment taking into account of economic
considerations.
Packaging
We participate in the recycling programmes of the countries in
which our products are sold to ensure optimum recycling.
All of our packaging materials are environmentally friendly and
can be recycled.
Old electrical and electronic appliances
Electrical or electronic devices that are no
longer serviceable must be collected
separately and sent for environmentally
compatible recycling (in accordance with the
European Waste Electrical and Electronic
Equipment Directive).
To dispose of old electrical or electronic
devices, you should use the return and collection systems put
in place in the country concerned.
10
Commissioning report
A51
6021 Collector
temperature sensor
faulty
Check configuration. The selected setting requires
a collector sensor
Change configuration.
Check connecting lead between solar module and
collector temperature sensor
Establish a connection properly
Check collector sensor according to table
(
technical documentation for solar modules)
If values do not match, replace the
sensor
A51
6022 Bottom temp. sensor
cylinder 1 faulty.
Standby mode active
Check configuration. The selected setting requires
a cylinder sensor at the bottom
Change configuration
Check connecting lead between solar module and
collector temperature sensor
Establish a connection properly
Check the electrical connection of the connecting
lead at the solar module
If a screw or plug is loose, rectify the
contact problem
Check bottom cylinder temperature sensor
according to table (
technical documentation
for solar modules)
If values do not match, replace the
sensor
A61
A62
A63
A64
1081
1082
1083
1084
Two master
programming units in
the system.
Check parameterisation at the installation level
(In the BUS system, further user interfaces are
configured as the controller in addition to the
Sense II)
Register the user interface for heating
circuit 1 – 4 as master
(Configure Sense I as remote control)
Hxx
No system fault.
For instance, service interval of heat source
elapsed.
Service required; see technical
documents for the heat source.
Fault
code
Sub-
code
Cause or fault
description
Test procedure/Cause
Corrective measure
Table 30 Fault displays
_
_
_
Table 31 During installation enter the ID number of the user interface here.