en | Configuration Using a Web Browser
VideoJet X10
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
5.35
Advanced Mode: Alarm Inputs
You can configure the alarm inputs of the VideoJet X10.
Alarm input
Select
Active high
if the alarm is to be triggered when the contact closes. Select
Active low
if
the alarm is to be triggered when the contact opens.
Name
You can enter a name for each alarm input, which is then displayed below the icon for the
alarm input on the
LIVEPAGE
if configured correctly (see
Section 5.15 Advanced Mode:
LIVEPAGE Functions, page 43
).
5.36
Advanced Mode: Relay
You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select
Open
if you want the relay to operate as an NO contact, or select
Closed
if the relay is
to operate as an NC contact.