DOC | V4.0 | 2009.06
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable
. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s
.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
–
Off
Relay is not triggered by events
–
Connection
Trigger whenever a connection is made
–
Video alarm
Trigger by interruption of the video signal
–
Motion alarm
Trigger by motion alarm, as configured on the
VCA
page (see
Section 5.31 Advanced
Mode: VCA Event Triggered, page 69
)
–
Local input
Trigger by the corresponding external alarm input
–
Remote input
Trigger by remote station's corresponding switching contact (only if a connection exists)
Relay name
You can assign a name for the relay here. The name is shown on the button next to
Trigger
relay
. The Livepage can also be configured to display the name under the relay icon.
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
i
NOTICE!
The numbers in the lists of selectable events relate to the corresponding connections on the
unit,
Video alarm 1
, for example to the
Video In
connection.