PATTERN SETUP
NO.
EDIT
TITLE
TIME
CLEAR
SAVE
BACK
1.
Select the option "NO.###" to select a pattern number.
2.
Select the appropriate pattern number.
3.
Select the option "Edit." A second screen PATTERN SETUP appears.
4.
Using the joystick, move to a desired target.
5.
Press the button [Near] to begin programming.
6.
Using the joystick, record the scene. Note that ’Time’ means recorded time. The maximum
amount of time available for recording is 60 seconds.
7.
Save the settings.
Note: Select the option "Clear" to delete the pattern.
Notice!
You can also edit the Pattern title. Select the option "Title," then edit the title following the
steps in Editing Titles, page 46.
Tour Setup
The camera has a maximum of 8 Tours in Pelco protocol mode, and 2 Tours in Bosch protocol
mode. Each tour can have 28 configurable items. Each item can be a pre-defined preset,
pattern, and scan in Tour 2-8. (Only Presets (28 maximum) can be inserted in Tour 1.) To set
up (program) a tour:
4
From the MAIN MENU, select TOUR SETUP. The screen TOUR SETUP appears.
TOUR SETUP
NO.###
(-TOUR1: PRESET ONLY)
10.9
AUTODOME 4000 Mini PTZ Dome
On-Screen Display (OSD) Menu | en
63
Bosch Security Systems, Inc.
Operation Manual
2015.08 | |