Service Manual
Singular Combi Boiler - BTC 439002301 A (12.2021)
7.9 Secondary Heat Exchanger
Part No.
7738007256*
Function
Main part for heat transfer from the burner
It has multiple paths of water tubes on the heat exchanger surface as
well as inside the combustion chamber.
Failure Event
Water and/or exhaust gas leakage through a crack
Improper heat transfer can cause the water in the heat exchanger to
boil due to possible scale formation
Effects
Leakage of exhaust gas
Excessive heating of water that produces boiling noises.
Error Code
AA, A4
Diagnostic
Visual inspection : Check if there is a crack on the surface of heat
exchanger.
Sound inspection : Check if boiling occurs inside the unit
Color/Number of Wires
N/A
Table 12
* part number is for fully assembled heat exchanger unit.
7.10 Sensor
Part No.
7738007297 (Sensor, Supply/Return)
Sensor, Heating/Return
Sensor, DHW
Exhaust Temperature Sensor (Blue)
7738007295 (Sensor, DHW)
7738007268 (Exhaust Temperature Sensor)
Function
Measure the temperature of the hot water, cold water, exhaust gas in the
boiler.
Failure Event
Unable to properly measure the temperature in the boiler.
Effects
Unable to shut combustion off when the water temperature from the
heat exchanger exceeds 203°F (95°C).
Unable to reach the hot water temperature set by user.
Unable to shut down the water heater when the flue gas temperature
from the exhaust duct exceeds 203°F (95°C).
Error Code
AA, AB, AC, E1, E2, E3, EB
Diagnostic
Visual inspection: Connection or breakage of wires.
Voltage check: Check range of voltage shown below.
Resistance check of the sensor.
Color/Number of Wires
Blue-Blue: DC 0 – 5 V
Table 13