Danger of lethal injury due to hazardous electric
voltage.
DANGER
●
Connect power supply units generating protective extra-low voltage (24 V) on-
ly to supply voltages designed for these power supply units. Comply with the
overvoltage categories, refer to
fig. 10-16 "Power routing 400 V" on page 38
●
Do not apply the supply voltage to the protective extra-low voltage
10.7.3 Wiring the embedded terminal
PE bar
B
Overvoltage category I
XD1
FE
VEP
24 V
6 mm² (blue)
A
A
0 V
2
1
2
2
1
10 mm (green/yellow)
2
①
Easy to remove and visible
②
Cable length b24 V power sup-
ply unit and the VEP is 6 m max. at a
minimum cross-section of 0.75 mm
2
. Ca-
ble length b24 V power supply
unit and the VEP is 10 m max. at a mini-
mum cross-section of 1.5 mm
2
. If the ca-
ble length exceeds 10 m, a separate
power supply unit is required.
A
Insulated terminal block
B
Non-insulated terminal block
FE Functional earth
Fig. 10-17: Wiring the Embedded Terminal
11 Commissioning
The product can be used directly. No configuration is required.
12 Device description
Depending on the operation (glove or finger), the multi-touch configuration is
different. Different parameter sets (standard, glove and extreme EMC-loaded op-
eration) of the multi-touch controller can be loaded using the IPC maintenance
tool. For special use cases, contact the Bosch Rexroth service.
VEP 15.6 Multi Touch, VEP 21.6 Multi
Touch
Bosch Rexroth AG
Device description
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P
39/53