⑧
Functional earth (FE)
⑨
Male connector strip X2
⑩
Male connector strip X3
Fig. 9-8: Male connector strips X2 and X3 of the keypad and functional earth connection
Death or lethal injury due to incorrect handling
of the E-STOP button
WARNING
●
The E-STOP button can be used as operating element in an E-STOP circuit
●
The E-STOP circuit has to be designed by the machine manufacturer
●
Only qualified staff may connect the E-STOP button and check it afterwards
●
It has to be connected acc. to the connection scheme
●
The max. load current is 500 mA
9.6.1 Connections
Name at the
housing
Connection
type
Connector type (integrated)
Mating connector
X2
Keypad con-
nection
Phönix pin contact strip,
6-pin,
SMC
1,5/6-
G-3,81-1827318
Phönix socket strip,
6-pin, FK-MCP 1,5/6-ST-3,81
X3
Keypad con-
nection
Phönix pin contact strip,
10-pin,
SMC
1,5/10-
G-3,81-1827350
Phönix socket strip,
10-pin, FK-MCP 1,5/10-ST-3,81
Tab. 9-6: Keypad connections
Bosch Rexroth AG
Interfaces
VEP 15.6 Multi Touch, VEP 21.6 Multi
Touch
22/53
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P