10.6 Mounting the VEP 15.6 housing devices
10.6.1 Installation notes
●
When mounting the embedded terminal, ensure an ergonomic operation. Ad-
ditionally, ensure that all moving machine components can be seen by the op-
erator at any time!
●
Avoid mounting locations exposed to direct sunlight, as the screen readability
is reduced and additional heat development can occur
●
When mounting the embedded terminal, ensure an easy access to the connec-
tor panel (top side)
●
Provide a minimum space of 50 mm (on all sides of the device) for sufficient
cooling and for cable routing
●
Lay all connecting cables in loops and use strain reliefs for all cables
●
Keep the maximum distance possible from interference sources
●
To maintain the degree of protection, use only cable grommets that fit to the
cable cross-sections for the cable bushing
Fig. 10-10: Cable bushing
●
Remove the cover at the rear side of the device to connect the cables. Re-
move the screws of the cover (see
②
in
fig. 10-11 "Position of the cover" on
) and then remove the cover
●
Connect all cables
●
After connecting all the cables, tighten the screws of the cover again
●
Ensure that the sealing of the cover is not damaged
●
Mount the cover correctly and fasten the screws with the correct tightening
torque
Loss of degree of protection due to incorrect
opening of the housing cover.
NOTICE
Ensure that the cover is mounted safely before switching on the device.