1070080029 / 05
Bosch Rexroth AG
Electric Drives
and Controls
PST 6xx0
|
|
232
/330
Information on this product
X11
X10
-
Power supply to the I/O module (24 V
DC
)
Terminals 1 and 3 linked internally
Terminals 2 and 4 linked internally
-
Signal outputs O0 to O7 (24V
DC
), with control LED
X11
X13
-
Signal inputs I0 to I7 (24V
DC
), with control LED
X12
X15
X14
Diagnosis messages of the module:
-
TR: Transmit/Receive; no meaning in this case.
-
CC: Cable check; bus connection (coming from the previous IB‐S
node) exists. Is switched off in the case of reset at the master.
-
UL: Unit Supply; illuminated: supply voltage is present (X10).
-
BA: Bus Active; illuminated: data transfer takes place.
-
RD: Remote Disable; illuminated: indicates that the bus connec
tion (to the next IB‐S node) is switched off.
-
FO1: Illuminated if incoming optical fiber disturbed.
-
FO2: Illuminated if outgoing optical fiber disturbed
INTERBUS-S connection IN for optical fiber connection
(coming from the previous IB‐S node)
INTERBUS‐S connection OUT for optical fiber connection
(going to the next IB‐S node)
Fig.12:
Front panel view: ”E/A IBS OPC with optical fiber“ I/O module
ENGLISH
Summary of Contents for Rexroth PST 6 0 Series
Page 12: ......
Page 152: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 152 330 Notizen Notes ...
Page 170: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 170 330 Notes ENGLISH ...
Page 176: ......
Page 316: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 316 330 Notes DEUTSCH ...
Page 320: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 320 330 Notes DEUTSCH ...