1070080029 / 05
Bosch Rexroth AG
Electric Drives
and Controls
PST 6xx0
|
|
294
/330
Service and repair
10.3.2
Firmware update via "FWUpdate"
For firmware update of all timers via the Ethernet field bus interface.
The following is needed to perform a firmware update
•
a PC with the "FWUpdate" software installed,
•
a working connection to the PC via the Ethernet field bus interface.
•
a BOS database installed on the PC with a valid timer reference
(BOS 6000 installed) and
•
the firmware as a *.hex file.
"
Proceed as follows:
1.
Start the "FWUpdate" software.
When the software is started, it will search for a valid timer reference
(is read from the BOS6000 database) and show you all properly lin
ked timers in tabular format:
2.
Use the "SST-Firmware" command button to select the path and file
name of the desired firmware.
Firmware files have the file name extension ”.hex”.
The selected firmware file will be displayed in the corresponding in
put fields.
3.
Select the timer(s) for which the firmware update is to be carried out
by ticking the proper check boxes at the left margin of the lines.
To select/deselect all of the timers, use the check box at the left mar
gin of the table's header line.
4.
Select the desired options for the firmware update by ticking the ap
propriate check box(es). These options will be applicable for all
selected timers.
ENGLISH
Summary of Contents for Rexroth PST 6 0 Series
Page 12: ......
Page 152: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 152 330 Notizen Notes ...
Page 170: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 170 330 Notes ENGLISH ...
Page 176: ......
Page 316: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 316 330 Notes DEUTSCH ...
Page 320: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 320 330 Notes DEUTSCH ...