Storage time/months
Measures for commissioning
> 1
> 12
> 60
●
●
Measure insulation resistance. Dry the winding at a value of < 1kOhm per volt
rated voltage.
●
Replace bearings
●
Replace encoders
Tab. 5-8: Measures before commissioning motors that have been stored over a prolonged
period of time
5.6 Shock load during transport und storage
MS2N motors comply with the transport condition requirements of class 2M4
(shock during transport) acc. to EN 60721-3-2 compare with
. Function-impairing effects are avoided as long as the specified
limits are complied with.
Frame size
Maximum allowed shock load (11 ms)
Axial
Radial
MS2N03, -04, -05
100 m/s²
1000 m/s²
MS2N06
500 m/s²
MS2N07
300 m/s²
MS2N10, 13
200 m/s²
Tab. 5-9: Permissible shock load for MS2N motors
The specified limit values do not apply to half-sine-shaped single shock load acc.
to EN 60068-2-27.
The specifications do not apply to motor operation. Applications
with continuous shock load make a case-by-case review necessary.
MS2N Synchronous Servomotors
47/101
Operating conditions and handling
R911347581_Edition 04 Bosch Rexroth AG
Summary of Contents for Rexroth MS2N
Page 1: ...MS2N Synchronous Servomotors Operating Instructions R911347581 Edition 04 ...
Page 18: ...XVI MS2N Synchronous Servomotors Bosch Rexroth AG R911347581_Edition 04 ...
Page 103: ...MS2N Synchronous Servomotors 81 101 R911347581_Edition 04 Bosch Rexroth AG ...