1
Sealing
2
Screwed connection
3
Cable sealing
4
Pressure piece
5
Union nut
6
Encoder cable
7
Power cables
8
Lid screws
9
Terminal box lid
Fig.11-2:
Connection of MKE037, -047, -098
1. Remove the lid screws (8) and take off the terminal box lid (9).
The lid screws are coated with TFL. By screwing in resp. out of lid
screws, the coating will be destroyed. When assembling the termi‐
nal box lid, use only the added, coated lid screws.
The Eexd-Cable screwings are mounted factory-attached. The seal‐
ing (1) is screwed with with the screwing (2) on the terminal box lid (9)
(tightening torque of Nm). – The terminal box includes the complete ac‐
cessory incl. assembly instruction.
2. Insert the union nut (5), the preasure piece (4) and the cable sealing (3)
in the indicated order over the power cable (7)
3. Tighten the screwing (2) with the sealing (1) within the terminal box lid (9)
with tightening torque of 50 Nm.
4. Insert the power cable (7) through the screwing (2) into the terminal box
lid (9).
5. Remove the EExd-Cable screwing for the encoder cable.
When using the ready-made cables of Rexroth, the EExd cable
screwing on the motor is not needed.
6. Insert the encoder cable (6) into the terminal box lid (9) (see
).
7. Tighten the screwing of the encoder cable (2) with the sealing (1) within
the terminal box lid (9) with tightening torque of 50 Nm.
8. Pull back the cable until the shrinking sleeve penetrates the inside of the
terminal box by about 16mm (see
).
102/131 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth MKE Synchronous Motors | Project Planning Manual
Installation