P
Load
PV
Electric losses
Θ
Temperature
Θmax
Highest temperature (motor housing)
t
Time
TC
Cycle durationCycle duration
ΔtP
Operating time with constant load
ΔtV
Idle timeIdle time
Fig.4-3:
Operating modes according to EN 60034-1:1998
Operating time
Operating mode S6 is supplemented by specification of the ON time (ED) in %.
The operating time is calculated as follows:
ED
Cyclic duration factor in %
ΔtP
Operating time with constant load
Fig.4-4:
Cyclic duration factor
The values specified in the documentation have been determined on the basis
of the following parameters:
Cycle duration: 15 min
Operating time (ED): 25%
If valid, conditions deviating therefrom are marked accordingly.
Project Planning Manual | Rexroth MKE Synchronous Motors
Electric Drives
and Controls
| Bosch Rexroth AG
25/131
Technical Data