When using ready-made encoder cables (see
) remove the fitting
which is mounted on the motor and use the fitting which is mounted on the
cable.
It is not necessary to define the cable's outer diameter.
(1)
Sealing
(2)
Screwing
(3)
Use grommets according to the cable diameter
(4)
Union nut
(5)
Ready-made power cable
(6)
Terminal box lid
(7)
Lid screws
(8)
Ready-made encoder cable
Fig.11-7:
Mounting of the EExd fitting and MKE118 cable
Loosen and tighten the cable fittings is not permitted. In this cases,
"new grommets" have to be used.
The cables, which are thread into the terminal box have be connected according
to
.
1. Connect the shield
Connect the ring terminal of the power and encoder cable on the X5 within
the terminal box lid
(Tightening torque 1.3 Nm 10%)
2. Connect the power cable
Lay the wires according to the connection plan (
) onto the terminal
block X1 and X2.
3. Connect the encoder plug
Mount the connection lock onto the encoder connector X3.
106/131 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth MKE Synchronous Motors | Project Planning Manual
Installation