(5)
EExd cable screwing
(6)
Encoder cable
(7)
Power cables
(8)
Lid screw tighten torque 6.3 Nm
(10),(11)
Shield connection screw tighten torque 1.3 Nm
X1
Plug-in terminal
X2
Plug-in terminal brake, temperature
X3
Encoder connector
X5
Shield connection
Fig.11-4:
Entry of power and conductor cables MKE 096
MKE118
Cable fittings
MKE118/EU motors of Rexroth are to be connected with Ex screwings espe‐
cially adapted to the cable's outer diameter.
Observe the notes of the manufacturer:
All cable entries of LE... type have to be included into the type test according
to EN 50018, Section 15.1.3 (overpressure test) according to the group clas‐
sification of the respective electrical equipments (group classification I, IIA, IIB
or IIC), if the operating pressure exceeds 20 bar.
The cable entries must be fastened into the electrical equipment in such a way
that they are secured against twisting and loosening.
The cable entry include a multiple-part set of sealing rings per nominal diameter
of the cables. The fitting sealing ring has to be selected and the union nut has
to be screwed as far as it will go.
When investigating the maximum current-carrying capacity of the connection
wires, assume the self-warming and housing-warming on the mounting place
at maximum permitted ambient temperature.
104/131 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth MKE Synchronous Motors | Project Planning Manual
Installation