3. Wait until the power supply unit switches off automatically after the UPS opera‐
tion.
4. Ensure that no voltage remains in the control cabinet PC. Disconnect the PC
power supply from the X10 connection if required.
5. Remove the five marked screws at the housing side, see
screws of the housing cover" on page 33
6. Open the housing cover.
7. Loosen the screw of a slot cover and remove the slot cover.
8. Insert the module cautiously and evenly. Ensure that the connections are inserted
into the connector on the main board.
9. Fasten the plug-in assembly with the screw used to fix the sheet.
10. Close the device door and fasten the five marked screws, see
of the screws of the housing cover" on page 33
If the card is equipped with a Plug and Play (PnP) function, it is automatically recog‐
nized by the operating system and integrated in the system, provided that there are no
hardware conflicts (IRQ etc.) with other extension cards or connected devices. Informa‐
tion on the error quest, see
chapter 13 "Error Causes and Elimination" on page 31
.
14.7
Exchanging the Housing Fan
1. Carry out step 1 to step 6, which are described in
2. Exchange the housing fan. The position of the fan is illustrated in
tion of the hard disk and of the fastening screws (inside)" on page 34
3. Carry out step 12 to step 14, which are described in
.
15
Ordering Information
15.1
Accessories and Spare Parts
For ordering information on accessories and spare parts, please refer to
"Spare Parts, Accessories and Wear Parts" on page 10
Bosch Rexroth AG
Ordering Information
DOK-SUPPL*-VSP*XX.3***-IT01-EN-P
Rexroth IndraControl VSP xx.3 Panel PC
36/43