Digital 24 V Input (Changeover Input)
The selection, which of the VDP displays connected to the Y-Repeater is
activated, occurs via a digital 24 V input.
As the image signals are transmitted to both VDP displays, data can only
be entered with the active VDP.
+
N.C.
-
X21
2
3
1
X21
1 2 3
X21.FH9
Fig. 7-17:
Assignment of the digital 24 V input
Pin
Labeling
Function
1
+
Signal input
2
-
Signal ground
3
N.C.
not assigned
Fig. 7-18:
Pin assignment X21
Input bit X21
Active VDP
0 (or open)
VDP1
1
VDP2
Fig. 7-19:
Selection of the active VDP
Connection method
2-wire connection
Reverse voltage protection
Yes
Input voltage:
Nominal value at “0”
Nominal value at “1”
-3 V ... + 5 V
11 V ... 30 V
Input current:
Nominal value at “0”
Nominal value at “1”
< 2,5 mA
2,8 mA ... 6 mA
Cable length (unshielded)
< 100 m
Short-circuit protection, overcurrent
protection
Typ. 0.6 A
Fig. 7-20:
Characteristic value of the digital 24 V input
Note:
During the booting process of the IPC you must not switch
from VDP1 to VDP2.
X21 –
Digital 24 V Input
Summary of Contents for Rexroth IndraControl VDP 16.1
Page 6: ...IV Contents VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 14: ...1 8 System Presentation VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 30: ...4 4 Technical Data VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 44: ...5 14 Dimensions VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 68: ...7 10 Interfaces VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 72: ...9 2 Touch Screen Software VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 82: ...12 4 Index VDP 16 1 VDP 40 1 and VDP 60 1 DOK SUPPL VDP16 40 60 PR02 EN P ...
Page 89: ......