Cable lengths
SVGA
800 × 600 pix‐
els
XGA
1024 × 768 pixels
SXGA
1280 × 1024 pix‐
els
Cable lengths between Y-re‐
peater and VDP
< 80 meters
< 70 meters
< 60 meters
Total cable length between
control cabinet PC and VDP
with Y-repeater
< 100 meters
< 100 meters
< 100 meters
Fig.10-8:
Cable lengths allowed for VAC01.1S-YD1-NNNN
Malfunctions if the total of all cable lengths ex‐
ceeds 100 m.
NOTICE
The total of all cable lengths between the control cabinet PC and the operator
VDP may not exceed 100 m.
If the total of all cable lengths between control cabinet PC and operator display
exceeds 30 m, the data transmission for USB devices connected to the VDP is
limited. See also chapter 7.2.3 "S1 DIP switch".
Fig.10-9:
Maximum cable length between operator display and control cabinet PC
Further cable lengths on request.
10.4.5
24 V Supply Voltage and Digital 24 V Input
The power consumption of the Y-repeater is 4 W.
Fig.10-10:
Assignment of the digital 24 V input
Bosch Rexroth AG
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
64/81
Y-Repeater