Designa‐
tion at the
housing
Connection type
Connector type (in‐
tegrated)
Mating connector or
cable (from outside)
XVID
CDI interface, screen
RJ45 female con‐
nector
RJ45 connector
XUSBIN
USB2.0 connection to the
control cabinet PC. Length 5
m max.
Only high-speed USB2.0 ca‐
bles are to be used (see
USB female con‐
nector, 4-pin, type B
USB connector, 4-
pin, type B
X2
Connection keypad
Phönix male con‐
nector strip, 6-pin,
MCV 1.5/6- G-3.5
Phönix female con‐
nector strip, 6-pin,
FK-MCP
1.5/6-
ST-3.5
X3
Connection keypad
Phönix male con‐
nector strip, 10-pin,
MCV 1.5/10-G-3.5
Phönix female con‐
nector strip, 10-pin,
FK-MCP
1.5/10-
ST-3.5
Fig.7-2:
Interfaces on the VDP 08.3 and VDP 40.3
7.2.3
S1 DIP Switch
Overview
Designation at the
housing
Switch type
Function
S1/switch 1
DIP switch
Without function
S1/switch 2
DIP switch
OFF: Cable length to the control cabinet PC <
30 m
ON: Cable length to the control cabinet PC >
30 m
Fig.7-3:
DIP switch on the VDP
Operation Modes
Cable length between control cabi‐
net PC and VDP is 5 m maximum
If the cable length to the control cabinet PC does not exceed 5 m, the USB
connection to the VDP can be executed in the USB 2.0 mode (High Speed,
max. 480 Mb/s) by using an additional USB 2.0 cable. The S1 switch 2 must
be in the "OFF" position. If the cable is not plugged, the USB connection is
executed in USB-1.1 (max. data rate at Full Speed: 12 Mb/s).
Cable length between control cabi‐
net PC and VDP max. 30 m (stand‐
ard USB mode)
The USB connection is executed in the USB1.1 mode. The S1 switch 2 must
be in the "OFF" position.
Malfunctions in the standard USB mode
caused by strokes!
NOTICE
No internal strokes are to be integrated into the connected USB device (be‐
cause of the additional runtime) so that the standard USB mode works with a
cable length of up to 30 m!
Bosch Rexroth AG
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
46/81