Fig.5-8:
VDP 40.3 DI, rear view
5.2
Mounting
5.2.1
Installation Notes
●
The display is to be installed in such a way that an ergonomic operation
is ensured. Additionally, ensure that all machine components can be seen
by the operator!
●
Avoid installation locations exposed to direct UV light/sunlight, as the
screen readability is reduced and additional heat development can occur.
●
The LED displays on the front panel have to be visible.
●
Lay all connecting cables in loops and use strain reliefs for all cables.
●
Keep as much distance as possible to noise sources.
For maintaining the degree of protection IP 54, use only cable grommets that
fit to the cable cross-sections for cable bushing, see
Designation of the cable grommet (mount‐
ing/sealing kit)
Cable diameter
QT4
4-5 mm
QT5
5-6 mm
QT6
6-7 mm
QT7
7-8 mm
QT8
8-9 mm
Bosch Rexroth AG
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
32/81