Parameter number
Parameter description
IDN/S-0-1301
List of GDP classes & version
Description
List of all GDP profiles (classes) supported
by the device
Data type, length List (32-bit), 1 entry
Write-protection
always
Default value
GDP_Basic (v1)
IDN/S-0-1302.0.1
FSP type & version
Description
FSP profile supported by the device
Data type, length List (32-bit), 1 entry
Write-protection
always
Default value
FSP_IO (v1)
IDN/S-0-1302.00.2
Function groups
Description
List of the I/O function groups supported by
the device
Data type, length List (IDN), variable
Write-protection
always
Default value
–
IDN/S-0-1302.00.3
Application type
Description
Description of the application in which the
device is used
Data type, length Text (ASCII), variable
Write-protection
Never
Default value
–
Tab. 9-2:
Function group identification (FG_Identification)
Parameter number
Parameter description
IDN/S-0-0095
Diagnostic message
Description
Diagnostic text
Data type, length Text (ASCII), variable
Write-protection
always
Default value
–
IDN/S-0-0099
Reset class 1 diagnostic
Description
Command to acknowledge class 1 errors
Data type, length Integer (binary), 16 bit
Write-protection
always
Default value
–
Bosch Rexroth AG
DOK-CONTRL-S67S3BKDI8*-AP03-EN-P
Rexroth IndraControl S67 Sercos Coupler 8 Digital Inputs (M8)
62/139
Sercos