24/60
Transport and storage
Bosch Rexroth AG
, A10VGT Series 11, RE 92770-01-B/11.2016
▶
Place the lifting strap around the axial piston unit in such a way that it does not
pass over attachments (e.g., valves, piping) and that the axial piston unit is not
suspended from attachments (see Fig. 6).
Fig. 6: Transport with lifting strap
6.2 Storing the axial piston unit
•
The storage areas must be free of corrosive materials and gases.
•
To prevent damage to the seals, ozone-forming equipment (e.g., mercury-vapor
lamps, high voltage equipment, electric motors, sources of electrical sparks or
electrical discharge) must not be operated in storage areas.
•
The storage areas must be dry.
Recommended relative humidity ≤ 60%.
•
Ideal storage temperature: +5 °C to +20 °C.
•
Minimum storage temperature: −50 °C.
•
Maximum storage temperature: +60 °C.
•
Keep out of direct sunlight.
•
Do not stack axial piston units and store them in a shock-proof manner.
•
Do not store the axial piston unit on the drive shaft or attachments, e.g., sensors
or valves.
•
For further storage conditions, see Table 7.
▶
Check the axial piston unit monthly to ensure proper storage.
The axial piston units are provided ex-works with corrosion protection packaging
(corrosion protection film).
Table 7 lists the maximum permissible storage times for an originally packed axial
piston unit as per data sheet 90312.
Table 7: Storage time with factory corrosion protection
Storage conditions
Standard corrosion protection long-term corrosion
protection (optional)
Closed, dry room, at a consistent
temperature between 5 °C and
20 °C throughout. Undamaged
and sealed corrosion protection
film.
Maximum 12 months
Maximum 24 months
Requirements
After delivery