40/60 Installation
Bosch Rexroth AG
, A10VGT Series 11, RE 92770-01-B/11.2016
If necessary, you can change the position of the connector by turning the solenoid.
This is not dependent on the connector version.
To do this, proceed as follows:
1.
Loosen the mounting nut with rubber boot (
1
) on the solenoid. To do this, turn
the mounting nut (
1
) one turn counter-clockwise.
2.
Turn the solenoid body (
2
) to the desired position.
3.
Re-tighten the mounting nut. Tightening torque of the mounting nut: 5
+1
Nm.
7.5 Performing flushing cycle
In order to remove foreign particles from the system, Bosch Rexroth recommends
a flushing cycle for the entire system before the initial commissioning. To avoid
internal contamination, the axial piston unit must not be included in the flushing cycle.
The flushing cycle must be performed with an additional flushing unit. Follow
the instructions of the flushing unit's manufacturer for the exact procedure
during the flushing cycle.
Changing connector
position
2