9 Operation
The product is a component which requires no settings or changes during operation.
For this reason, this chapter of the manual does not contain any information on
adjustment options. Use the product only within the performance range specified in
the technical data. The machine/system manufacturer is responsible for the proper
project planning of the hydraulic system and its control.
9.1 Manual override of the electrical control
NOTICE
Danger from improper handling!
Proportional solenoid can be damaged!
▶
Do not actuate the manual override with a sharp tool.
The valves of the electrical control (EP) are equipped with a manual override.
Where necessary or in the event of a fault (e.g. electrical fault), the adjustment of
the axial piston unit can be changed manual via manual override.
The manual override is only designed for brief manual actuation; it must not be
moved to a specific switch position by means of mechanical equipment for either
a longer period of time or permanently.
The manual override device is not suitable for frequently recurring manual actuation!
▶
Press the left or right rubber foot on the electrical control (EP) until the desired
adjustment position is reached.
After the emergency actuation is released, the control returns to its neutral
position.
Fig. 14: Manual override for electrical control