Gateway address
If you want the unit to establish a connection to a remote
location in a different subnet, enter the IP address of the
gateway. Otherwise, leave the box blank (
0.0.0.0
).
DNS server address
The unit can use a DNS server to trigger an address of a mail or
FTP server specified as a name. Enter the IP address of the DNS
server.
Video transmission
If the unit is operated behind a firewall,
TCP (HTTP port)
should be selected as the transfer protocol. For use in a local
network, select
UDP
.
HTTP browser port
Select a different HTTP browser port from the list if required.
The default HTTP port is 80. If you want to allow only secure
connections via HTTPS, you must deactivate the HTTP port. In
this case, select
Off
.
HTTPS browser port
If you want to allow browser access on the network via a secure
connection, select an HTTPS browser port from the list if
necessary. The default HTTPS port is 443. Select the
Off
option
to deactivate HTTPS ports; only unsecured connections will
now be possible.
The camera uses the TLS 1.0 encryption protocol. You may
need to activate this protocol via your browser configuration.
You must also activate the protocol for the Java applications
(via the Java control panel in the Windows control panel).
CAUTION!
Multicast operation is only possible with the UDP protocol. The
TCP protocol does not support multicast connections.
The MTU value in UDP mode is 1,514 bytes.