Dinion IP Infrared Imager
Configuration via IP, Advanced Mode | en
81
Bosch Security Systems, Inc.
User Manual
F.01U.263.416 | 3.1 | 2012.09
2.
If necessary, click
Clear All
first to clear the current
selection (fields marked yellow).
3.
Left-click the fields to be activated. Activated fields are
marked yellow.
4.
If necessary, click
Select All
to select the entire video
frame for monitoring.
5.
Right-click any fields that you want to deactivate.
6.
Click
OK
to save the configuration.
7.
Click the close button
X
in the window title bar to close
the window without saving the changes.
Tamper detection
You can reveal the tampering of cameras and video cables by
means of various options. Run a series of tests at different
times of the day and night to ensure that the video sensor is
operating as intended.
Sensitivity
The basic sensitivity of the tamper detection can be adjusted
for the environmental conditions to which the camera is
subject.
The algorithm reacts to the differences between the reference
image and the current video image. The darker the observation
area, the higher the value that must be selected.
Trigger delay(s)
You can set delayed alarm triggering. The alarm is only triggered
after a set time interval in seconds has elapsed and then only if
the triggering condition still exists. If the original condition has
NOTICE!
The options for tamper detection can only be set for fixed
cameras. Dome cameras or other motorized cameras cannot be
protected in this manner as the movement of the camera itself
causes changes in the video image that are too great.
NOTICE!
This and the following parameter are only accessible if the
Reference check
checkbox is activated.