Dinion IP Infrared Imager
Configuration via IP, Basic Mode | en
45
Bosch Security Systems, Inc.
User Manual
F.01U.263.416 | 3.1 | 2012.09
Time server type
Select the protocol that is supported by the selected time
server. Preferably, you should select the
SNTP server
as the
protocol. This supports a high level of accuracy and is required
for special applications and subsequent function extensions.
Select
Time server
for a time server that works with the
protocol RFC 868.
8.3
Basic Mode: Network
The settings on this page are used to integrate the camera into
an existing network.
Some changes only take effect after the unit is rebooted. In this
case, the
Set
button changes to
Set and Reboot
.
1.
Make the desired changes.
2.
Click the
Set and Reboot
button. The camera is rebooted
and the changed settings are activated.
DHCP
If your network uses a DHCP server for the dynamic assignment
of IP addresses, you can activate acceptance of IP addresses
automatically assigned to the camera.
Certain applications (VIDOS, Bosch Video Management System,
Archive Player, Configuration Manager) use the IP address for
the unique assignment of the unit. If you use these applications,
the DHCP server must support the fixed assignment between IP
address and MAC address, and must be appropriately set up so
that, once an IP address is assigned, it is retained each time the
system is rebooted.
IP address
Enter the desired IP address for the camera in this field. The IP
address must be valid for the network.
CAUTION!
If you change the IP address, subnet mask or gateway address,
the camera is only available under the new addresses after the
reboot.