86
en | Configuration via IP, Advanced Mode
Dinion IP Infrared Imager
F.01U.263.416 | 3.1 | 2012.09
User Manual
Bosch Security Systems, Inc.
9.6
Advanced Mode: Interfaces
9.6.1
Relay
You can configure the switching behavior of the relay outputs.
For each relay, you can specify an open switch relay (normally
closed contact) or a closed switch relay (normally open
contact).
You can select different events that automatically activate an
output. It is possible, for example, to turn on a floodlight by
triggering a motion alarm and then turn the light off again when
the alarm has stopped.
Idle state
Select
Open
if you want the relay to operate as an NO contact,
or select
Closed
if the relay is to operate as an NC contact.
Select
Select the relay:
–
External Device - Triggers the output relay from the
network?.
–
IVA - Triggers the output relay on? IVA.
–
Mono Mode - Triggers the output relay in Mono mode.
–
IR Filter Toggle - Triggers the output relay just before the
IR filter starts moving and opens when video level has
stabilized (2 to 3 seconds).
Name
You can assign a name for the relay here. The name is shown on
the button next to
Trigger relay.
The
LIVEPAGE
can also be
configured to display the name under the relay icon.
Furthermore, in the Forensic Search program, you can use the
name as a filter option for quick search through the recordings.
CAUTION!
Do not use any special characters, for example
&
, in the name.
Special characters are not supported by the system's internal
recording management and may therefore result in the Player or
Archive Player programs being unable to play back the
recording.