37
Presented by Bob Pattengale
BOSCH MTS 5200 LAB SCOPE
1-800-71-TRAIN (1-800-718-7246) OR www.auto-video.com
Signal Finder
4-Channel Oscilloscope
NAVIGATING THE MTS 5200 (CONTINUED)
If you have correctly configured the oscilloscope but see no waveform on the touch screen
display, Signal Finder provides a quick and easy way to find the signal and display it. Signal
Finder examines the input signal and automatically adjusts the settings for your selected
channels in order to display the signal. Be sure that the channel is ON and the test leads are
connected to the correct test port.
Signal Finder adjusts the Volts/Div, Ground Offset, and Trigger Level settings to the signal. The
Trigger Edge, Trigger Mode, Trigger Source, and Trigger Position settings are not adjusted but set
to default values.
Cursors
In the oscilloscope live mode, Freeze mode, and Playback mode you can enable two horizontal
and two vertical cursors to make precise measurements of waveforms displayed on the grid. You
can turn the cursors on and off, and lock them so that they move together to maintain their
relative delta measurements.
The active cursors are displayed as solid horizontal and vertical lines extending the entire height
or width of the waveform display area. The inactive cursors are displayed as dashed horizontal
and vertical lines.