The power connection is made in single or double wiring. The ready-made
power cables are inserted into the terminal box via the adapter plates and ca‐
ble glands with optional reductions/extensions.
Power cable connection on termi‐
nal box
Connecting the power cable to the terminal box requires the following steps:
1.
Open the terminal box cover.
Loosen and remove the mounting screws (4 pieces).
2.
Turn terminal box if necessary.
Loosen the mounting screws ⑩ and turn the terminal box by 90 or 180
degrees. Screw in and tighten the mounting screws ⑩ . Tightening tor‐
que of the screws ⑩: 6.5 Nm (± 10%)
Ensure that the seal between the terminal box and motor housing is in
proper condition and in the correct position.
3.
Remove the protective cover of the cable gland.
4.
Detach the adapter plate ③ from the terminal box.
5.
Screw the adapter plate firmly to the metric cable gland on the power
cable. Use reduction for power core cross-sections of 1.5 mm² and
2.5 mm².
Before attaching the power cable to the adapter plate, check the correct
condition and position of the O-ring.
6.
Feed the power cable up to the adapter plate through the opening in the
terminal box and fasten the adapter plate to the terminal box.
Tightening torque of the screws ⑥: 9 Nm (±10%)
Before attaching the adapter plate ⑥ to the terminal box, check the O-
ring ⑤ inserted in the adapter plate for proper condition and correct po‐
sition.
7.
Connect the cores according to the connection diagram for standard or
double cabling.
Observe the following tightening torques:
Designation
Type
Connection
mm²
Size / type
Tightening torque
Nm
Clamping power
U1, V1, W1
WEF
1.5 … 16 (RLK1200)
1.5 … 35 (RLK1300)
M6
2.5
Clamping 1 ... 6
temperature sen‐
sor / holding brake
(option)
WEF
0.2 … 2.5
Spring-cage terminal
-
Ring terminal end
for PE and screen RTE
M8
3.8
WEF = wire end ferrules
RTE = ring terminal end
Tab. 12-4:
Screw tightening torques in Nm in terminal box
8.
Close and fasten the terminal box cover.
Apply Loctite 243 (liquid screwlock) to the thread of the mounting
screws for the lid ① and then attach the lid with all of the mounting
screws.
Tightening torque of the screws: 6.5 Nm (±10%)
Before attaching the terminal box cover to the terminal box, check for
proper condition and the correct position of the glued seal ② on the ter‐
minal box cover.
DOK-MOTOR*-MSK********-PR12-EN-P
Bosch Rexroth AG
255/279
Synchronous Servomotors MSK
Installation
Summary of Contents for MSK030B-0900-NN
Page 1: ...Synchronous Servomotors MSK Project planning manual R911296289 Edition 12 ...
Page 12: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 10 279 Synchronous Servomotors MSK ...
Page 24: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 22 279 Synchronous Servomotors MSK ...
Page 160: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 158 279 Synchronous Servomotors MSK ...
Page 180: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 178 279 Synchronous Servomotors MSK ...
Page 238: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 236 279 Synchronous Servomotors MSK ...
Page 242: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 240 279 Synchronous Servomotors MSK ...
Page 248: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 246 279 Synchronous Servomotors MSK ...
Page 260: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 258 279 Synchronous Servomotors MSK ...
Page 268: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 266 279 Synchronous Servomotors MSK ...
Page 274: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 272 279 Synchronous Servomotors MSK ...
Page 276: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 274 279 Synchronous Servomotors MSK ...
Page 280: ...Notes Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 278 279 Synchronous Servomotors MSK ...
Page 281: ...Notes DOK MOTOR MSK PR12 EN P Bosch Rexroth AG 279 279 Synchronous Servomotors MSK ...