In addition to the information and notes on the holding brake given here, ad‐
ditional standards and guidelines must be observed when designing the sys‐
tem.
In the area of European countries e.g.:
●
EN 954; ISO 13849-1 and ISO 13849-2 Safety-related parts of control
units
●
Information Sheet No. 005 “Gravity loaded axes (vertical axes)” - pub‐
lished by: Technical Committee Mechanical Engineering, Manufacturing
Systems, Steel Construction
For the US:
●
See National Electrical Code (NEC), National Electrical Equipment Man‐
ufacturers Association (NEMA) and regional building codes.
The national regulations must be observed!
The permanent magnetic brake is no safety brake. This means, a torque re‐
duction by non-influenceable disturbance factors can occur (see EN 954; ISO
13849-1; ISO 13849-2 or Information Sheet No. 005 “Gravity loaded axes
(vertical axes)”).
Particular attention must be paid to this:
●
Corrosion on the friction surfaces as well as vapors, exhalations and de‐
posits reduce the braking effect.
●
Lubricants must not get onto the friction surface.
●
Over-voltages and excessively high temperatures can permanently
weaken the permanent magnets and thus render the holding brake un‐
usable.
If the air gap between armature and pole increases due to wear, the function
of the holding brake is no longer guaranteed.
Checking the holding brake during
operation (recommendation)
Faults which occur during the operating period and which may change the
design parameters or the operating conditions must be detected and elimina‐
ted within a reasonable period of time. In this case, we recommend checking
the function and condition of the holding brake at regular intervals.
9.10.3
Design of holding brakes
Holding brakes on motors are generally not designed for service braking. The
effective braking torques are physically different in static operation and dy‐
namic operation.
Normal operation and EMERGENCY
STOP
Malfunction
In normal operation, using the holding
brake for clamping an axis in standstill,
the “static holding torque” (M4) – static
friction takes effect.
At an EMERGENCY STOP for stopping
an axis (n < 10 min
-1
), a “dynamic brak‐
ing torque” (M
dyn
) - sliding friction - takes
effect.
In the event of a malfunction, using the
holding brake to stop an axis in motion (n
≥ 10 min
-1
) , a “dynamic braking torque”
(M
dyn
) - sliding friction - takes effect.
M4 > M
dyn
Therefore, please note the following description of the dynamic design.
Tab. 9-9:
Dynamic design
Bosch Rexroth AG
DOK-MOTOR*-MSK********-PR12-EN-P
222/279
Synchronous Servomotors MSK
Operating conditions and application notes
Summary of Contents for MSK030B-0900-NN
Page 1: ...Synchronous Servomotors MSK Project planning manual R911296289 Edition 12 ...
Page 12: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 10 279 Synchronous Servomotors MSK ...
Page 24: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 22 279 Synchronous Servomotors MSK ...
Page 160: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 158 279 Synchronous Servomotors MSK ...
Page 180: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 178 279 Synchronous Servomotors MSK ...
Page 238: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 236 279 Synchronous Servomotors MSK ...
Page 242: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 240 279 Synchronous Servomotors MSK ...
Page 248: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 246 279 Synchronous Servomotors MSK ...
Page 260: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 258 279 Synchronous Servomotors MSK ...
Page 268: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 266 279 Synchronous Servomotors MSK ...
Page 274: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 272 279 Synchronous Servomotors MSK ...
Page 276: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 274 279 Synchronous Servomotors MSK ...
Page 280: ...Notes Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 278 279 Synchronous Servomotors MSK ...
Page 281: ...Notes DOK MOTOR MSK PR12 EN P Bosch Rexroth AG 279 279 Synchronous Servomotors MSK ...