7.2.5
Fan units electrical connection
Connection 1-phase
RLS0780
Clamping range cable gland 7 ... 10 mm
Fig. 7-3:
Fan connection 1-phase with protection switch
LEM fan units in “T” version with integrated thermal protection do not require
wiring with an external motor protection switch.
Protection against wrong connection!
●
230V: L1 to pin 1
●
115V: L1 to pin 3
Bosch Rexroth AG
DOK-MOTOR*-MSK********-PR12-EN-P
186/279
Synchronous Servomotors MSK
Accessories
Summary of Contents for MSK030B-0900-NN
Page 1: ...Synchronous Servomotors MSK Project planning manual R911296289 Edition 12 ...
Page 12: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 10 279 Synchronous Servomotors MSK ...
Page 24: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 22 279 Synchronous Servomotors MSK ...
Page 160: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 158 279 Synchronous Servomotors MSK ...
Page 180: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 178 279 Synchronous Servomotors MSK ...
Page 238: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 236 279 Synchronous Servomotors MSK ...
Page 242: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 240 279 Synchronous Servomotors MSK ...
Page 248: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 246 279 Synchronous Servomotors MSK ...
Page 260: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 258 279 Synchronous Servomotors MSK ...
Page 268: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 266 279 Synchronous Servomotors MSK ...
Page 274: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 272 279 Synchronous Servomotors MSK ...
Page 276: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 274 279 Synchronous Servomotors MSK ...
Page 280: ...Notes Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 278 279 Synchronous Servomotors MSK ...
Page 281: ...Notes DOK MOTOR MSK PR12 EN P Bosch Rexroth AG 279 279 Synchronous Servomotors MSK ...