en | Configuration using a Web browser
MIC Series IP Power Supply
F.01U.265.804 | 1.6 | 2012.08
User Manual
Bosch Security Systems, Inc.
4.
Select the output option:
–
None: no defined command.
–
Alarm Relay: defines a physical connection from the open collector alarm output.
–
Aux On: defines a standard or custom keyboard ON command.
Note
: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
–
Aux Off: defines a standard or custom keyboard OFF command.
Note
: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
–
Shot: defines a preset scene from shot 1-99.
–
Transmit: Transmits a message back to the head end (available with RS-232 serial
and Bilinx connections).
5.
Select the Output period, which controls the length of time the output relay is activated:
–
Follow: Alarm output will remain activated for the same amount of time the alarm
input is activated
–
Latched: Alarm stays on until the operator clears it.
4.28.4
Alarm States
This page identifies the status of each alarm set in the system.
4.29
Miscellaneous
Password
Enter a password for the encoder.
Address
Allows the appropriate camera to be operated via the numerical address in the control
system. Type a number between 0000 and 9999, inclusive, to identify the camera.
Reset to Factory Defaults