MIC Series IP Power Supply
Configuration using a Web browser | en
65
Bosch Security Systems, Inc.
User Manual
F.01U.265.804 | 1.6 | 2012.08
4.37
Advanced Mode: Alarm
4.38
Alarm Connections
You can select how the encoder responds to an alarm. In the event of an alarm, the unit can
automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to
which the encoder will connect in sequence in the event of an alarm, until a connection is
made.
Connect on alarm
Select On so that the encoder automatically connects to a predefined IP address in the event
of an alarm.
By setting Follows input 1 the unit maintains the connection that has been automatically
established for as long as an alarm exists on alarm input 1.
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit
contacts the remote stations one after the other in the numbered sequence until a connection
is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten
passwords for connecting to remote stations. If connections to more than ten remote stations
NOTICE!
In the default setting, Stream 1 is transmitted for alarm connections. Bear this fact in mind
when assigning the profile (see
Section 4.20 Encoder Profile, page 44
).