User Function 34 - Camera Indicator
This function is used to enable an onscreen indicator to identify a pan/tilt
equipped camera. Move the joystick up or down to select
DISP CAM
CONTROL
or
NO CAM CONTL DISPL
. Press
[Enter]
to activate your
selection. When enabled, cameras identified as controllable (via User
Function 35 or the optional LTC 8059/00 MCS package), show a
in the middle of the first line of monitor text.
User Function 35 - Controllable Cameras
Priority 1 users can use this function to select camera sites equipped with pan/tilt
devices. Move the joystick up or down to select the camera number, and left or right
to select
FIXED
or
MOVABLE
. User Function 34 or the optional PC software pack-
age enables or disables the display of the controllable camera indicators on the sys-
tem monitor displays.
User Function 36 - Select Crosspoint Data
Use this function to select options for accessory device data that can be sent out the
biphase control port. Move the joystick up or down to select
XPOINT DATA
,
ALARM
XPOINT
, or
PHYSICAL CAMERA NUMBER
, and left or right to enable/disable the
selected option. These options are typically applicable only when LTC 8770 Series
Switcher Follower accessory devices are being used in the system.
User Function 37 - R/D Address Mode
Priority 1 users can use this function to select whether the biphase control data com-
mands will be addressed using the cameras' logical numbers or physical number
indexes in the Camera Table. Move the joystick up or down to select
LOGICAL
or
PHYSICAL
and press
[Enter]
to activate your selection. If this option is set to
LOGI-
CAL
, AutoDome Series cameras and Allegiant Series receiver/drivers should be
addressed using the cameras' logical identification number. If it is set to
PHYSICAL
,
the devices should be addressed using the cameras' physical port number.
User Function 38 - Printer Port Mode
This function allows configuration of the system's
PRINTER
port for use with a
LTC 8712 Series Console Port Expander accessory device. Move the joystick up or
down to select the printer port function;
NORMAL
or
EXPANDED
. Press
[Enter]
to
activate your selection. Reset the system for this setting to take effect.
User Function 39 - Select DIU Interface Port
Use this function to select the switcher's interface port to be connected to an external
LTC 8016/90 Allegiant Bilinx Data Interface accessory unit. Move the joystick up or
down until the desired port for use as a data interface (DIU) is displayed. Press
[Enter]
to configure the port. If using the LTC 8555 keyboard, press
[User]
to exit
the mode.
User Function 40 - Reserved Function
User Function 41 - Set Satellite Communication Format
This function provides three (3) configuration options that determine the behavior
and content of the data commands issued by a master system to a satellite system. In
most cases, it is only necessary to change the default setting if using a multi-level cas-
Summary of Contents for LTC 8016/90
Page 2: ...EN ii Bosch Security Systems December 13 2005 ...
Page 79: ...Replacement of Memory Backup Batteries EN 69 Figure 15 LTC 8500 Character ROM Table ...
Page 101: ...Product Instruction Manual Important Safeguards EN 91 ...
Page 102: ...Product Instruction Manual Safety Precautions EN 92 Bosch Security Systems December 13 2005 ...
Page 103: ...Product Instruction Manual FCC ICES Information EN 93 ...